2. DESCRIPTION
2.1 General
Bluetooth built-in: fully configurable with a tablet or smartphone
Low battery voltage alarm trip and reset levels
Low battery voltage cut-off and restart levels
Dynamic cut-off: load dependent cut-off level
Output voltage: 210 - 245V
Frequency: 50 Hz or 60 Hz
ECO mode on/off and ECO mode sense level
Alarm relay
Monitoring:
In- and output voltage, % load and alarms
For more information, refer to the
VE.Direct communication port
The VE.Direct port can be connected to a computer (VE.Direct to USB interface cable needed) to configure and monitor the same
parameters.
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load turn on level: 10VA; and
min load turn off level: 0VA). Once in standby the inverter will switch on for a short period (adjustable, default: every 3 seconds). If the
load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, between battery plus and the left hand contact of the two pole
connector or between battery minus and the right hand contact of the two pole connector
LED diagnosis
See section 3.3
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less
than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption. Alternatively use a