Installation Instructions
3. Slowly attempt to tilt the range forward.
If you encounter immediate resistance, the range foot is engaged in the
anti-tip bracket. Go to Step 9.
4. If the rear of the range lifts more than 1/2" (1.3 cm) off the floor without
resistance, stop tilting the range and lower it gently back to the floor. The
range foot is not engaged in the anti-tip bracket.
IMPORTANT: If there is a snapping or popping sound when lifting the range,
the range may not be fully engaged in the bracket. Check to see if there are
obstructions keeping the range from sliding to the wall or keeping the range
foot from sliding into the bracket. Verify that the bracket is held securely in
place by the mounting screws.
5. Slide the range forward, and verify that the anti-tip bracket is securely
attached to the floor or wall.
6. Slide range back so the rear range foot is inserted into the slot of the
anti-tip bracket.
7. Repeat steps 1 through 3 to ensure that the range foot is engaged in the
anti-tip bracket.
If the rear of the range lifts more than 1/2" (1.3 cm) off the floor without
resistance, the anti-tip bracket may not be installed correctly. Do not
operate the range without anti-tip bracket installed and engaged.
8. Move the range into its final location, and check that the range is level by
placing a carpenter's level on the bottom of the oven.
NOTE: The range must be level for optimum cooking and baking
performance.
9. If needed, use a wrench to adjust the height of the leveling legs until the
range is level from side to side and front to back.
22
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas
pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel, authorized
gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion or fire.
LP/PROPANE GAS CONVERSION
This appliance can be used with Natural Gas or LP/Propane gas. It is shipped
from the factory for use with natural gas. A kit for converting to LP gas must
be purchased separately.
When the cooktop is converted for liquid petroleum (LP) gas, the LP gas
supply is required to provide a minimum of 10" to a maximum of 14" water
column to the cooktop regulator.
The conversion must be performed by a qualified service technician in
accordance with the kit instructions and all local codes and requirements.
Failure to follow instructions could result in serious injury or property damage.
The qualified agency performing this work assumes responsibility for the
conversion.
24
25
Gas Conversion
WARNING
23