7. User instructions.

7.1. Foreseen use and adjustments.
We suggest to start the filter twice a day for 4 or 5 hours.
7.1.1.
Use and functioning of the multifunctional valve.
Always switch off the pump when operating on the multifunctional valve's lever.
It is recommended to install valves in the inlet and outlet pipelines (hydraulic parts).
FILTRATION.
The water in the pool enters the multifunctional valve from the PUMP connector (Fig. 18,
# 1), travels through the filter media (from top to bottom), exits from the POOL connector
(Fig. 19, # 3) and returns clean to the pool.
BACKWASH.
The water in the pool enters the multifunctional valve from the PUMP connector (Fig. 18,
# 1), travels through the filter media (from bottom to top) stirring it, exits from the WASTE
connector (Fig. 18, # 4) getting rid of the impurities held back by the filter media.
RINSE.
The water in the pool enters the multifunctional valve from the PUMP connector (Fig. 18,
# 1), travels through the filter media (from top to bottom) compacting it, exits from the
WASTE connector (Fig. 18, # 4) getting rid of the impurities held back by the filter media.
VALVE CLOSE (only on 6-way multifunctional valve).
The water in the pool does not cross the filter. The PUMP connector (Fig. 18, # 1) is
closed.
WASTE (only on 6-way multifunctional valve).
The water in the pool enters the multifunctional valve from the PUMP connector (Fig. 18,
# 1), exits straight from the WASTE connector (Fig. 18, # 4) without going through the
filter media.
CIRCULATION (only on 6-way multifunctional valve).
The water in the pool enters the multifunctional valve from the PUMP connector (Fig. 18,
# 1) and exits from the POOL connector (Fig. 18, # 3) going back to the pool without
crossing the filter media.
WINTER.
Rest position of the multifunctional valve to protect the internal components of the
multifunctional valve itself. Position suitable for storage.

8. Routine, scheduled and extraordinary maintenance.

Before proceeding with any maintenance activity, remember to disconnect the power plug from the power outlet, and not to put your hands in the water if the
product (pump) is turned on.
Do not lubricate and/or use detergents and/or chemical products to clean the product.
Replace damaged components and/or deteriorated as quickly as possible, use only original spare parts. For this purpose, please consult the "Retail and spare
parts and relevant documentation".
8.1. Routine maintenance.
To be performed at least once a year, or more frequently if necessary.
The filter maintenance is limited to its own cleaning through the BACKWASH. Start it at least once a week for 2-3 min. and after each bottom cleaning.
Carry out a BACKWASH after each cleaning of the bottom or when the pressure on the gauge equals the pressure stated in Tab. 1 (backwash).
A rinse of about 30 seconds must follow each BACKWASH.
It is essential to filter twice a day for 4-5 hours, to regularly backwash (for 2÷3 minutes) and to wash the pool bottom at least once a week so that the pool water
remain cleaned!
Product components that, due to their normal use, suffer wear and/or tear must be regularly replaced to ensure good product performance. The following table
shows the perishables and/or consumables used in the product and their estimated working life.