  • FRANÇAIS, page 1
LEROY-SOMER
VMA
VMA
terminal
terminal
Designation
33/34
31/32
6
6
aDIo3
7
7
DIo1
8
5
24V
11
11
9
8
DI2
10
9
DI3
12
10
DI4
13
na
sDI1
14
12
sDI2/ena
15
13
com/Rl1
16
na
Rl1c
17
14
Rl1o/Rl2
18
na
sDo1
19
na
sDo2
InstallatIon anD maIntenance
VARMECA 30
Variable speed motor or geared motor
Function
characteristics
Voltage input
Full scale voltage
Input impedance
current input
current range
Input impedance
Resolution
sampling
analogue or logic input or
logic input (if connected to the +24V)
analogue output 3
thresholds
Assignment in standard
Voltage range
configuration: Analogue
output (LED control option for
load
VMA 31 up to 34)
Input threshold
Voltage output
Voltage range
load resistor
Protection
current output (VMA 33/34 only)
current range
maximum voltage
load resistor
characteristics
thresholds
Voltage range
sampling/refreshment
Digital input or output 1
Digital input
Assignment in standard
absolute maximum voltage range
configuration:
load
External fault management
Input threshold
logic output
maximum output current
overload current
output current
overload current
+24V internal source
accuracy
Protection
characteristics
logic input 2
Assignment in standard
thresholds
configuration: Run forward
Voltage range
sampling/refreshment
logic input 3
Assignment in standard
absolute maximum voltage range
configuration: Run reverse
logic input 4
load
Assignment in standard
configuration: Selection of ADI1
Input threshold
type 0-10 V or 4-20 mA reference
characteristics
+24V dedicated to the safety
input
thresholds
Voltage range
safety/unlocking input
Impedance
characteristics
Fault relay output
250 Vac maximum contact
current
characteristics
safety contact
250 Vac maximum contact current
3776 en -
2013.06 / k
Characteristics
analogue voltage (common mode) or uni-directional current
10 V ± 2%
95 kW
0 to 20 ma ± 5%
500 W
10 bits
6 ms
«0»: < 5 V – «1»: > 10 V
0 to +24 V
95 kW
7.5 V
0 to 10 V
2 kW
short-circuit (40 ma max)
0 to 20 ma
10 V
500 W
Digital input or output 1
«0»: < 5 V – «1»: > 10 V
0 to +24 V
2 ms
0 to +35 V
15 kW
7.5 V
50 ma
50 ma
Vma 31/32 : 30 ma - Vma 33/34 : 100ma
Vma 31/32 : 60 ma - Vma 33/34 : 150ma
± 5%
current limiting and setting to fault mode
logic input (positive logic)
«0»: < 5 V – «1»: > 10 V
0 to +24 V
2 ms
0 to +35 V
15 kW
7.5 V
logic input (positive logic)
«0»: < 5 V – «1»: > 18 V
9 to +33 V
820 W
Vma 33/34: no_nc single-pole changeover contact
Vma 31/32: no single-pole contact
- 4 a, resistive load
- 2 a, inductive load
no single-pole changeover contact
- 4 a, resistive load
- 2 a, inductive load
17