Block Diagrams

A1+ A2
ST1
overvoltage and
monitoring
short circuit protection
K1
24V
phase
M11685
RK 5942.01
A1+ A2
S11
S12
overvoltage- and
monitoring
short circuit protection
logic
K1
24V
power
M9220_b
RK 5942.02
A1+ A2
S11
S12
overvoltage- and
monitoring
short circuit protection
logic
K1
24V
power
M9223_c
RK 5942.03
ST2
13 S28+
K1
K1/K2
logic
K2
K2
K1/K2
28
14
S34
13
+
K1
K1/K2
K2
K2
K1/K2
14
28
S34
11
K2
K1
K2
K1/K2
13
14

Technical Data

Input
Nominal voltage U
:
N
Voltage range
at 10 % residual ripple:
Nominal consumption:
Control voltage on ST1
or S11:
Control current:
Recovery time:
Output
Contacts
RK 5942.01, RK 5942.02:
RK 5942.03:
The semiconductor output can only be used for monitoring. The con-
tact S28+ must not be connected after the e-stop contact e.g. to A1
of the e-stop module.
Operate delay:
Release delay:
Contact type:
Thermal current I
:
th
Nominal output voltage:
Switching capacity
to AC 15:
NO contacts:
to DC 13:
NO contacts:
Electrical life
at 5 A, AC 230 V cos ϕ = 1:
according to DC 13
semiconductor output:
Output voltage
at 100 mA:
Permissable operating
frequency:
Short circuit strength
max. fuse rating:
line circuit braker:
Mechanical life:
General Data
Operating mode:
Temperature range
operation:
storage :
altitude:
Clearance and creepage
distances
rated impuls voltage /
pollution degree:
EMC
nterference suppression:
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire fixing:
Mounting:
Weight:
Dimensions
Width x height x depth
RK 5942.01; .02; .03:
RK 5942.01PC:
RK 5942.01PCA:
Mounting depth:
16
DC 24 V
DC 0.9 ... 1.1 U
N
2.2 W
typ. DC 22,5 V
typ. 95 mA
0.5 s
1 NO contact,
1 semiconductor monitoring output
2 NO contacts, with common source terminal
typ. 80 ms
typ. 70 ms
Forcibly guided
max. 5 A
(see continouos current limit curve)
AC 250 V
3 A / AC 230 V
IEC/EN 60 947-5-1
2 A / 24 V
IEC/EN 60 947-5-1
> 10
switching cycles
5
DC 24 V, 100 mA, short circuit strong
(see continouos current limit curve)
21.5 V
600 switching cycles / h
6 A gL
IEC/EN 60 947-5-1
B 6
10 x 10
switching cycles
6
Continuous operation
- 15 ... + 55 °C
- 25 ... + 85 °C
< 2.000 m
4 kV / 2 (basis insulation) IEC 60 664-1
IEC/EN 61 326-3-1, IEC/EN 62 061
Limit value class B
EN 55 011
IP 40
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplastic with V0 behaviour
according to UL subject 94
Amplitude 0.35 mm
frequency 10 ... 55 Hz, IEC/EN 60 068-2-6
15 / 055 / 04
IEC/EN 60 068-1
EN 50 005
Plus-minus terminal screws
M 3.5 box terminals or cage clamp
terminals
DIN rail
IEC/EN 60 715
110 g
17,5 x 90 x 71 mm
17,5 x 122 x 71 mm
17,5 x 124 x 71 mm
64 mm
RK 5942 / 26.07.16 en / 745