Idex Fast & Fluid Management Giotto Compact Consignes D'installation Et D'utilisation

Dispenser manuel

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Fast & Fluid Management Srl
A Unit of IDEX Corporation
Fast & Fluid Management Srl
Via Pelizza da Volpedo n° 109/111
20092 Cinisello Balsamo ( Mi)
Italy
Tel.
: +39 02.66091.1
Fax
: +39 02.66091.550
Web : www.fast-fluid.com
_______________________________________________________________________________________________
GIOTTO COMPACT
DISPENSER MANUALE
MANUAL DISPENSER
DISPENSER MANUEL
Installazione – Istruzioni operative
Installation – Operating instructions
Installation – Instructions pour opérer
1155007C-it,en,fr.doc – 16/10/2003
Pag. 2
Page 12
Page 22

Publicité

Table des Matières
loading

Sommaire des Matières pour Idex Fast & Fluid Management Giotto Compact

  • Page 1 Fast & Fluid Management Srl A Unit of IDEX Corporation GIOTTO COMPACT DISPENSER MANUALE MANUAL DISPENSER DISPENSER MANUEL Installazione – Istruzioni operative Pag. 2 Installation – Operating instructions Page 12 Installation – Instructions pour opérer Page 22 Fast & Fluid Management Srl Via Pelizza da Volpedo n°...
  • Page 2 Fast & Fluid Management Srl A Unit of IDEX Corporation 1.- INTRODUZIONE Il dispenser manuale Giotto e' un prodotto principalmente studiato per il dosaggio di coloranti per l' edilizia, alcune delle sue parti sono particolarmente precise per garantire risultati di dosaggio in accordo con lo standard dei produttori piu' importanti.
  • Page 3 Fast & Fluid Management Srl A Unit of IDEX Corporation 3.- MONTAGGIO Individuare la fiancata destra (2) e quella sinistra (3). Porre il pannello superiore (1) nella corretta posizione di assemblaggio. Assemblare utilizzando le viti tipo “C”. Montare alle fiancate (2) e (3) il pannello posteriore (4) e il tirante (8) utilizzando viti tipo “B”.
  • Page 4 Fast & Fluid Management Srl A Unit of IDEX Corporation 4- COLLEGAMENTO DEL COMPUTER Inserire la CPU sul ripiano intermedio e fare uscire i cavi dai fori posti sulla struttura. Appoggiare il monitor al piano d' appoggio superiore. Appoggiare la tastiera incastrando i piedini della tastiera stessa negli appositi alloggiamenti.
  • Page 5 Fast & Fluid Management Srl A Unit of IDEX Corporation Regolare il timer (2) su un tempo di circa 5 minuti e controllare se la macchina lavora correttamente. Durante questa fase, la piastra dei contenitori deve venire ruotata in tutte le posizioni fino a quella iniziale.
  • Page 6 Fast & Fluid Management Srl A Unit of IDEX Corporation SCHEMA 6 Mettere in funzione l' apparecchio (agitatore elettrico) mediante l' azionamento dell' interruttore principale e del timer. 7.-COLLAUDO Regolare le astine (1) e (2) della pompa di dosaggio, al valore massimo ed azionare , i pistoni corrispondenti (ROSSO e NERO) su e giu’...
  • Page 7 Fast & Fluid Management Srl A Unit of IDEX Corporation 8.- ELIMINAZIONE DELL' ARIA Regolare l' astina della pompa nera sul valore 3Y (2) e l' astina della pompa rossa sul valore 19 (1) (SCHEMA 8). Aspirare il prodotto mediante sollevamento dei pistoni (3). Aprire la valvola (SCHEMA 9), estrarre il prodotto e versarlo in un recipiente vuoto, appositamente preparato, mediante spinta del pistone fino alla posizione inferiore finale.
  • Page 8 Fast & Fluid Management Srl A Unit of IDEX Corporation 9.- ISTRUZIONI PER IL DOSAGGIO Assicurarsi di aver identificato il colore desiderato nell' elenco delle formule. Idenificare la misura del barattolo per la corretta quantita' e mettere il barattolo del colorante base aperto sul ripiano direttamente sotto l' ugello della valvola.
  • Page 9 Fast & Fluid Management Srl A Unit of IDEX Corporation Verificare che dalla valvola e dal canestro non ci siano perdite, se richiesto sostituire l' "O" Ring smontando la valvola come indicato nello (SCHEMA 9). Quando il canestro viene svuotato per la pulitura e la manutenzione e' necessario ripetere il processo di "Preparazione Dispenser".
  • Page 10: Avvertenze

    Fast & Fluid Management Srl A Unit of IDEX Corporation l' unita' del pistone. Estrarre il pistone interno dal pistone esterno. Togliere la guarnizione usurata (tutti i quattro pezzi) senza danneggiare il pistone. Lavare ed asciugare molto accuratamente le guarnizioni.
  • Page 11 Fast & Fluid Management Srl A Unit of IDEX Corporation riempire di nuovo con colorante fresco. _______________________________________________________________________________________________ 1155007C-it,en,fr.doc – 16/10/2003...
  • Page 12 Fast & Fluid Management Srl A Unit of IDEX Corporation 1.- INTRODUCTION Giotto manual dispenser is a product particularly developed for dosing the colourants for building paints, some of its parts are particularly precise to guarantee dosing results in compliance with the standard of the most important producers.
  • Page 13 Fast & Fluid Management Srl A Unit of IDEX Corporation 3.- ASSEMBLY Identify the right side (2) and the left one (3). Put the superior plate (1) in the corret assembly position. Assemble using screws type “C”. Assemble on the sides (2) and (3) the back panel (4) using screws type “B”.
  • Page 14 Fast & Fluid Management Srl A Unit of IDEX Corporation DIAGRAM 2 4.- CONNECTION OF THE COMPUTER Insert the CPU on the intermediate shelf and pass cables through the holes on the frame. Position the monitor on the superior plate.
  • Page 15 Fast & Fluid Management Srl A Unit of IDEX Corporation 5.- CONTROL Operate the main switch (1) (DIAGRAM 4).The green led (3) will light : this means that the electrical supply is connected. Set the timer (2) with a time of about 5 minutes and check that the machine works correctly.
  • Page 16 Fast & Fluid Management Srl A Unit of IDEX Corporation DIAGRAM 6 Start up the stirring device, by switching on the main switch and setting the timer. 7.- TESTING Set the rods (1) and (2) of the pump to the maximum level and move the corresponding pistons (Red and Black) up and down in a normal manner but with the distribution tap closed.
  • Page 17 Fast & Fluid Management Srl A Unit of IDEX Corporation 8.- ELIMINATION OF THE AIR Set the rod of the black pump on the value 3Y (2) and the rod of the red pump on the value 19 (1) (DIAGRAM 8).Draw in the colourant by lifting the pistons (3). Open the valve tap (DIAGRAM 9)push the pistons down to the bottom position forcing the colourant out of the pump and into an empty container placed under the tap.
  • Page 18 Fast & Fluid Management Srl A Unit of IDEX Corporation 9.- DOSING INSTRUCTIONS Be certain to have identified the colour from your formula data base. Identify the can size for the correct quantity and place the open can of base paint on the shelf directly under the nozzle of the valve.
  • Page 19 Fast & Fluid Management Srl A Unit of IDEX Corporation 11.- CONTAINER CLEANING Extract all paint from the containers Put inside about 1 liter water and let operate for about 15 minutes together with the simultaneous action of the stirrers Empty completely the containers operating the pumps : in this way it is possible to clean the containers, the pistons and the valve.
  • Page 20 Fast & Fluid Management Srl A Unit of IDEX Corporation 12.- NOTES If when starting the device through the rotation of the main switch to position "1" the green led doesn't light, extract the electrical plug from the socket tap and control the lamp. If necessary substitute it If the switch returns automatically to position "O"...
  • Page 21 Fast & Fluid Management Srl A Unit of IDEX Corporation 13.- FURTHER NOTES The electrical plug has to be connected to a mains socket which is correctly earthed. During any maintenance operation or by any intervention on the machine , the electrical plug must absolutely be extracted from the socket.
  • Page 22: Emballage

    Fast & Fluid Management Srl A Unit of IDEX Corporation 1.- INTRODUCTION Le dispenser manuel Giotto est un produit étudié principalement pour le dosage des colorants pour l'industrie du bâtiment; quelque partie du dispenser est particulièrement précise pour assûrer des résultats de dosage conformes au standard des producteurs les plus importants.
  • Page 23 Fast & Fluid Management Srl A Unit of IDEX Corporation Identifier la joue droite (2) et celle gauche (3). Placer le panneau supérieur (1) dans la position d'assemblage correcte. Assembler en utilisant les vis type “C”. Sur les joues (2) et (3) monter le panneau postérieur (4) et le tirant (8) en utilisant des vis type “B”.
  • Page 24: Connexion De L'ordinateur

    Fast & Fluid Management Srl A Unit of IDEX Corporation 4.- CONNEXION DE L'ORDINATEUR Placer la UC sur le rayon moyen et faire sortir les câble des trous de la structure. Poser le moniteursur la surface d'appui supérieure. Poser le clavier et bloquer ses pieds dans les relatifs sièges.
  • Page 25: Chargement Et Fonctionnement

    Fast & Fluid Management Srl A Unit of IDEX Corporation Actionner l'interrupteur principal (1) (SCHÉMA 4). La lumière verte (3) va s'allumer: ce signifie que l'alimentation électrique est correcte. Régler le timer (2) sur une durée de environ 5 minutes et vérifier si la machine travaille correctement.
  • Page 26 Fast & Fluid Management Srl A Unit of IDEX Corporation SCHÉMA 6 Mettre l'appareil (agitateur électrique) en fonction en agissant sur l'interrupteur principal et le timer. 7.- ESSAI Régler les tiges (1) et (2) de la pompe de dosage sur la valeur maximale et actionner les relatifs pistons (ROUGE et NOIR) (3) de façon régulière, mais avec le soupape de distribution fermé.
  • Page 27 Fast & Fluid Management Srl A Unit of IDEX Corporation 8.- ELIMINATION DE L'AIR Régler la tige de la pompe noire sur la valeur 3Y (2) et la tige de la pompe rouge sur la valeur 19 (1) (SCHÉMA 8). Aspirer le produit au moyen du soulèvement des pistons (3). Ouvrir le soupape (SCHÉMA 9), extraire le produit et le verser dans un récipient vide, expressement...
  • Page 28: Entretien

    Fast & Fluid Management Srl A Unit of IDEX Corporation 9.- INSTRUCTIONS POUR LE DOSAGE Vérifier d'avoir identifié la couleur desirée dans la liste des formules. Identifier la mesure du pôt pour la correcte quantité et placer le pôt du colorant de base ouvert sur le rayon, directement sous la buse du soupape.
  • Page 29: Nettoyage Des Conteneurs

    Fast & Fluid Management Srl A Unit of IDEX Corporation Vérifier l'absence de déperditions du soupape et du panier; si nécessaire remplacer l' "O" Ring après avoir démonté le soupape comme illustré dans le (SCHÉMA 9). Quand le panier vient vidé pour le nettoyage et l'entretien il faut répéter le processus de "Préparation Dispenser".
  • Page 30 Fast & Fluid Management Srl A Unit of IDEX Corporation Si l'interrupteur continue a déclancher automatiquement sur la position "O", essayer à l'actionner de nouveau après quelque minute. Si le même problème se répète, demander l'intervention d'un technicien. En cas de déperditions de la pompe, remplacer les garnitures (chaque machine fournie è...
  • Page 31: Problemes Et Possibles Solutions

    Fast & Fluid Management Srl A Unit of IDEX Corporation Avant d'allumer la machine par actionnement du timer, vérifier que tous les couvercles des conteneurs ont étés correctement bloqués. L' emission de bruit relative à la station de travail est au-dessous de 70 dB.

Table des Matières