WallPerfect spray attachment
i
Interior wall paint in strong colour shades should be applied at least twice
(allow first paint coat to dry first). This will ensure good coverage.
Assembly (fig. 1)
The nozzle, air cap and needle for the WallPerfect spray attachment are white. You cannot
combine different-coloured parts of other attachments. The parts could be damaged.
Slide the nozzle seal (Item 3) with the groove (slot) facing forwards into the nozzle. Put
the nozzle onto the gun body and find the correct position by turning it. Put the air cap
onto the nozzle and tighten it using the union nut. The device may only be used with
seals in perfect condition.
Aligning suction tube (refer to the instructions of the basic device)
If the suction tube is positioned correctly, the container contents can be sprayed
without almost any residue.
i
We recommend orienting the feed tube to the rear, to ensure optimal
coating of walls and ceilings.
Adjusting the material quantity
Very high quantities can be processed with this attachment. To prevent paint runs on the
object, first adjust the paint quantity by spraying onto a piece of card or paper from the
same spraying distance.
First turn the adjustment knob (Fig. a, Item 7) fully to the left (-) and then slowly increase
the material quantity to the desired amount by turning it to the right (+).
i
An average flow setting provides the best result for most wall paints.
CAUTION!
The units may only be used with a functional valve. If paints rises in the
ventilating hose (Fig. 1 A, item 12) do not operate the unit further!
Dismantle and clean the ventilating hose, valve and diaphragm and replace
the diaphragm if necessary.
Do not lay the spray gun.
Assembly
The unit may only be operated with an integer diaphragm (Fig. 1 A, 14). Place the diaphragm
with the pin facing upwards on the bottom section of the valve. Also see the marking
on the gun body. Place on the valve cover and screw it closed. Place the ventilating hose
on the valve cover and on the nipple at the gun body.
Slide the nozzle seal (Item 3) with the groove (slot) facing forwards into the nozzle
(Fig. 1 B). Put the nozzle onto the gun body and find the correct position by turning it. Put
the air cap onto the nozzle and tighten it using the union nut.
Place the container seal from below on the suction tube and slide it over the collar, while
turning the container seal slightly. Insert the suction tube with container seal in the gun
body.