Product Instructions
Viega MegaPress
½" to 2" Fittings
®
Model XXXX.XX
1
2
7
8a
d
9c
10
EN
Viega MegaPress ½" to 2" Fittings
Viega products are designed to be
installed by licensed and trained plumbing
and mechanical professionals who are
familiar with Viega products and their
installation. Installation by non-professionals
may void Viega LLC's warranty.
Cut piping at right angles using displacement type
1
cutter.
2
Keep end of piping a minimum of 4" away from
the contact area of the vise to prevent possible
damage to the piping in the press area. See
MegaPress Manual for minimum clearance
required for prep tools.
Remove burr from inside and outside of piping and
3
prep to proper insertion depth using a preparation
tool or fine grit sandpaper.
4
Check seal and grip ring for correct fit. Do not use
oils or lubricants.
3
min. 4"
8b
5
Illustration demonstrates proper fit of grip ring,
separation ring, and sealing element.
6
Mark proper insertion depth. Improper insertion
depth may result in an improper seal. The
depth marking shall be visible on the completed
assembly.
Pipe Size (in)
½
¾
1
2
7
Refer to chart for minimum distance between
fittings. To ensure a correct press, a minimum
distance between press fittings must be
maintained. Failure to provide this distance may
result in an improper seal.
Pipe Diameter (in)
½
¾
1
2
EN
This document is subject to updates. For the most current Viega
technical literature please visit www.viega.us.
ES
Este documento está sujeto a actualizaciones. Para obtener la
documentación técnica más reciente de Viega, visite www.viega.us.
FR
Viega LLC
Le présent document est soumis à des mises à jour. Pour consulter
les manuels techniques Viega les plus récents, veuillez vous rendre
585 Interlocken Blvd.
sur : www.viega.us.
Broomfield, CO 80021
Phone (800) 976-9819
www.viega.us
4
5
8c
9a
8a
Viega MegaPress ½" to 1" fitting connections must
Insertion Depth (in)
be performed with MegaPress jaws. See the pressing
1
/
1
tool's Operator's Manual for proper tool instructions.
16
1
/
8b
Open the MegaPress jaw and place at right angles
3
16
on the fitting. Visually check insertion depth using
1⅜
mark on piping.
1
/
13
16
8c
Start pressing process and hold the trigger until
1⅞
the jaw has engaged the fitting.
2
9a
Viega MegaPress 1¼" to 2" fitting connections
must be performed with MegaPress rings and
V2 actuator. See the pressing tool's Operator's
Manual for proper tool instructions.
9b
Open the MegaPress ring and place at right
angles on the fitting. The MegaPress ring must be
engaged on the fitting bead. Check insertion depth.
9c
Place V2 actuator onto the MegaPress ring and
d (in)
d (mm)
start pressing process. Hold the trigger until the
¼
6
actuator has engaged the MegaPress ring.
10
¼
6
Remove the MegaPress jaw from the fitting or
¼
6
release the V2 actuator from the MegaPress ring
and then remove the MegaPress ring from the
½
13
fitting on completion of press. Remove control
½
13
label to indicate press has been completed.
½
13
Product Instructions
Viega MegaPress ½" to 2" Fittings
Instrucciones del producto
Accesorios Viega MegaPress de ½" a 2"
Instructions produit
Raccords MegaPress de Viega ½" à 2"
PI-MP 520493 1219 MegaPress ½" to 2" Fittings (EN ES FR)
6
6
9b
Warning!
Keep extremities and foreign objects away
from press tool during pressing operation
to prevent injury or incomplete press.

Publicité

loading

Sommaire des Matières pour Viega MegaPress

  • Page 1 585 Interlocken Blvd. sur : www.viega.us. Broomfield, CO 80021 Phone (800) 976-9819 www.viega.us PI-MP 520493 1219 MegaPress ½" to 2" Fittings (EN ES FR) Model XXXX.XX min. 4" Illustration demonstrates proper fit of grip ring, Warning! separation ring, and sealing element.
  • Page 2 Retire la mordaza MegaPress del accesorio o l’outil de sertissage pour obtenir des instructions de banco para evitar posibles daños a la tubería libere el actuador V2 del anillo MegaPress y, al appropriées pour cet outil. en la zona de prensado. Consulte el manual de finalizar el prensado, retire el anillo MegaPress del Ouvrez la mâchoire MegaPress et placez-la à...