Note: There is no defect in this case; only
an indication that, as specified above, the
air volume has reduced and the low pres-
sure has increased.

Shutting down

 Turn the unit off (position "0").
 Rinse out the accessory parts with wa-
ter if necessary and dry them.
 Tap the cartridge filter and rinse inside
and outside with running water. Place
the cartridge filter with the rubber side
facing downwards onto a storage place
and leave it to dry or place the suction
head onto the floor and let the suction
turbine run. The air flow dries the car-
tridge filter. If the cartridge filter is too
dirty or damaged, then it is necessary to
replace it with a new one.
Note: Empty and clean the vacuum cleaner
after every use and whenever necessary.
 Empty the container.
 Vacuum and wipe the appliance inside
and outside.
 Place the appliance in a dry room and
secure it from unauthorized use.
 While vacuuming the appliance, use at
least one vacuum cleaner of the same
or higher classification.

Transport

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
 During the transport and maintenance
of the appliance the extraction opening
is to be closed with the connection
socket.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Maintenance and care

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Dust extracting machines are safeguards
for the prevention or elimination of hazards
defined in the regulations of BGV A1.
In order to carry out maintenance work,
the user must disassemble, clean and
service the unit, in so far as this is pos-
sible without endangering maintenance
personnel and other persons. Suitable
precautions include decontamination
before the unit is disassembled. Pre-
cautions must be taken for local filtered
forced air ventilation at the place where
the unit is disassembled, the cleaning of
the maintenance surface and suitable
protection of the personnel.
The outside of the unit should be
cleaned thoroughly and any harmful
substances removed. Alternatively, a
sealed coating may be applied before
the unit is removed from the danger ar-
ea. All unit parts are to be considered
contaminated when they are removed
from the danger area. To avoid distribu-
tion of the dust, you must take the ap-
propriate measures.
In the framework of maintenance and
repair work all contaminated objects
that cannot be cleaned satisfactorily
must be disposed of. Such objects must
be disposed of in impermeable bags in
accordance with the valid provisions for
the disposal of such waste.
– 4