Cleaning:
1.
Please pull out plug before cleaning.
2.
Use soft semi-dry cloth to clean the machine. Don't
use chemical agents, such as benzene, alcohol,
gasoline and so on, otherwise the machine surface
will be damaged, or even the machine itself.
3.
Don't spatter water into the machine.
Filter screen:
1.
Wash the filter screen once every two weeks. If it is
blocked by dust, efficiency of the A/C will be reduced.
2.
Take out the air inlet grille and pull out the filter
screen at both sides according to the direction shown
in the following figures.
3.
Put the filter screen into the warm water (about 40℃)
added with neutral detergent, dry it at a shady place
after cleaning.
Season Cleaning:
If the machine will be unused for a long time, please do
as following:
1.
Pull out drainage plug to flow out water.
2.
Let the machine runs under fan mode for 2 hours to
dry out the machine internal.
3.
Turn off machine and pull out plug.
4.
Clean and dry filters, then reinstall them.
5.
Pull out exhaust pipe for safekeeping.
6.
Put the machine into plastic bag, and place it on a dry
place.
7.
Remove batteries of the remote control and keep
them properly.
TROUBLE SHOOTING
If conditions listed below occurs, please check the following items before calling
the customer service.
Troubles
Possible Causes
Not plug in
The display panel
The A/C doesn't
displays"FL"
work
Time OFF function is
started.
Direct sunlight
Doors and windows keep
open; there are lots of
people or heat source
The A/C starts
in room.
frequently
Filter screen is very dirty
Air inlet or air outlet is
blocked
Noisy
The ground is not level or
not flat enough.
The compressor
Its delay protection is
doesn't work.
started.
If problems not listed in the table occur or recommended solutions do not work,
please contact the professional service organization.
74 | 75
GB
Suggested Remedies
Plug in
Restart the A/C after power off and
draining, then it will become normal
The A/C can be restarted 3 minutes
after being turning off.
Draw the curtain.
Close doors and windows, remove
heat source.
Clean or replace it.
Remove the blockage.
Place the unit on a flat, level ground
if possible.
Wait for 3min., turn on it after
temperature decreases.