Area Measurement
Press the area measuring button
measuring. The symbol for area measurements appears in the upper part
of the display.
Volume Measurement
Press the volume measuring button
ume measurement. The symbol for volume measurement appears in the
upper part of the display.
Continuous Measurement (see Fig.
The continuous measurement serves for the transfer of dimensions, for
example, from construction plans. With continuous measuring, the instru-
ment can be moved relative to the target with the measured value being
updated approximately every 0.5 s. For example, the user can move
back from a wall until he reaches the desired distance with the actual dis-
tance always being readable.
To set the unit to the continuous measurement mode, press the
button 1. The symbol
The continuous measuring switches off automatically after 10 min. The
last measured value remains in the display.
For earlier ending of the continuous measuring, change the measuring
function with one of the function buttons.
1 609 929 E86 • (02.12) T
Then measure the length and width one after
the other as for a length measurement. After
completing the second measurement, the re-
sult is automatically calculated and displayed.
The individual measured values are shown in
the upper right of the display, the results at the
bottom.
Then measure the length, width and height
one after the other as for a length measure-
ment. After completion of the third measure-
ment, the result is automatically calculated
and displayed.
The individual measured values are shown in
the upper right of the display, the results at the
bottom.
Note: Values of more than 9999999 cu.ft
cannot be displayed. For larger values, switch
to the "m
"m/ft" button 10.
www.kreitel-vermessungsgeraete.de
appears in the display.
To initiate the measurement process, press
the measurement button 7 completely down.
Move the measuring instrument until the de-
sired distance value is shown at the bottom of
the display.
By pressing the measure button 7, the contin-
uous measuring is interrupted. The current
measured value is shown in the display. Again
pressing the measure button 7 starts the con-
tinuous measuring anew.
American English–8
5 to switch to the mode for area
11 to switch to the mode for vol-
3
" unit of measure by pressing the
)
C