4000 Series
Art. 4901
Digital codelock module
PROGRAMMING
• Enter the ENGINEER'S CODE: first time type six times 1 (111111
factory preset) and press ENTER (The red LED will illuminate);
• Confirm ENGINEER'S CODE (typing again the same) or
type the new code (4 to 8 digits) then press ENTER (Melo-
dy). Pressing twice the ENTER button without changing the
ENGINEER'S CODE, will exit from the programming;
• Enter the code (4 to 8 digits) to enable RELAY 1 or re-enter the
existing code then press ENTER (Melody);
• Enter the RELAY 1 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
• Enter the code (4 to 8 digits) to enable RELAY 2 or re-enter the
existing code then press ENTER (Melody);
• Enter the RELAY 2 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
• Enter the code (4 to 8 digits) to enable RELAY 3 or re-enter the
existing code then press ENTER (Melody);
• Enter the RELAY 3 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
• The system is ready to use (the red LED will be off ).
PROGRAMMING NOTES
• After pressing enter following a command, press ENTER a fur-
ther twice to exit the programming menu.
RETURN SYSTEM TO PRESET ENGINEER'S FACTORY CODE
• Turn off power to code lock;
• Keep ENTER button pressed while turning the power back on;
• Release ENTER button;
• The engineer's code is now set to 111111 (six times one).
OPERATION
• Type in the programmed code and press ENTER;
• If the code is correct, the green LED will illuminate for approx. 2 seconds and the relay relevant to the code will operate for the
programmed time;
• If a wrong code is entered, a continuous melody will sound for 4 or more seconds, according to the number of mistakes;
• To switch off any relay while operating, type in the relevant code then press the CLEAR button;
OPERATION NOTES
• To operate relays together, set the same code for each relay;
• If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will
operate only when the correct code is entered.
ADHESIVE GASKET PLACEMENT
seal as shown in Fig. 5.
Apply the
Y
ANTI-TAMPERING LOCKS FIXING
Fit the anti-tampering locks
Art. 4901
- Installation instructions
as shown in Fig. 6.
W
"ENGINEER'S CODE"
Press Enter
(Red LED will
be ON)
Press Enter
"ENGINEER'S CODE"
(melody)
"ACCESS 1 CODE"
Press Enter
(melody)
"ACCESS 1 TIME"
Press Enter
(melody)
"ACCESS 2 CODE"
Press Enter
(melody)
"ACCESS 2 TIME"
Press Enter
(melody)
"ACCESS 3 CODE"
Press Enter
(melody)
"ACCESS 3 TIME"
Press Enter
(melody)
READY TO USE
Y
Fig. 5
- 3 -
First time six times
ENTER THE
1 "111111" factory
preset
Type again six times
CONFIRM
"1" or the new en-
OR CHANGE
gineer's code 4 to 8
digits
ENTER
Code to enable relay 1
4 to 8 digits
Two digits (01 to 99)
ENTER
i.E. 05=5 Seconds
00= remain open
ENTER
Code to enable relay 2
4 to 8 digits
Two digits (01 to 99)
ENTER
i.E. 05=5 Seconds
ENTER
Code to enable relay 3
4 to 8 digits
ENTER
Two digits (01 to 99)
i.E. 05=5 Seconds
SYSTEM
Red led will be off
G
Fig. 6
66251780 - V1.3 - 15/10/21
W

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

49014800m

Table des Matières