DESCRIPTION
Intelligent intercom with "door open/intercommunicating call"
push button, bus relay (Art.  2305) activation button and call
tone volume control (3 levels). To reduce bus current all apart-
ment devices are in a sleep mode when not used. In case a user
forgot to replace the handset, each operation must be executed
within 10 seconds of lifting the handset otherwise the handset
returns to its sleep state. To then perform an operation it would
be necessary to hang up the handset and pick it up again.
PUSH BUTTONS, LED'S AND CONTROLS
Door open button
During a conversation, with the handset lifted, press to
operate the lock.
Intercommunicating call
For an intercommunicating call, pick up the handset
and press as many times as the extension or address
value to call (see SW3 Intercommunication Settings).
Activate bus relay board Art. 2305 button
To activate a bus relay pick up the handset and press as
many times as the address value of the relay.
Call tone volume control
3 levels switch.
Art. 3183 - Installation instructions
A
B
C
D
E
F
G
Fig. 2
LEGEND
A
Door open button
Intercommunicating call
B
Activate bus relay board Art. 2305 button
C
Call tone volume control
D
Impedance termiantor (S1)
Intercommunication setting switches (SW3)
E
F
Unit address switches (SW1)
G
Connection terminals
DIP-SWITCHES AND JUMPERS
SW1 Unit address
Switches from 1 to 7 are used for unit address (from 1
to 99 binary coded). Last switch (8) is not used
SW3 Intercommunication setting
Switches 1,2 and 3 are used to for intercommunication
settings. Switch 4 is not used.
S1
Impedance terminator
The jumper must be normally closed. When more vid-
eophones/intercoms are connected in parallel (from
a peripheral to another and so on until the last) the
jumper must be open for all the intercoms except for
the last following the connection order.
- 1 -
S1
LB
AL
GND
BUS
BUS
66251760 - V2.3 - 15/05/22

Publicité

loading

Sommaire des Matières pour Videx 3183

  • Page 1 Call tone volume control the last following the connection order. 3 levels switch. - 1 - Art. 3183 - Installation instructions 66251760 - V2.3 - 15/05/22...
  • Page 2 The number of emitted beeps will be 1 for 3 rings or 2 for 6 rings. Each time this operation is carried out the number of rings is switched between the values 3 and 6. - 2 - Art. 3183 - Installation instructions 66251760 - V2.3 - 15/05/22...
  • Page 3: Technical Specifications

    Supplied by the BUS line Local Bell contact (put a push button between this ter- minal and the relevant GND terminal) Alarm input (not implemented) GND Ground signal Bus contacts - 3 - Art. 3183 - Installation instructions 66251760 - V2.3 - 15/05/22...
  • Page 4 (da un dispositivo all’altro fino all’ultimo) il jum- per deve essere aperto per tutti I citofoni ad eccezione Regolazione volume nota di chiamata dell’ultimo in ordine di collegamento. Switch 3 livelli. - 4 - Art. 3183 - Istruzioni di installazione 66251760 - V2.3 - 15/05/22...
  • Page 5 Un bip indica l’impostazione di 3 squilli mentre 2 bip indicano l’impostazione di 6 squilli. Ogni volta che questa operazione viene eseguita viene commutato il numero di squilli da 3 a 6 e viceversa. - 5 - Art. 3183 - Istruzioni di installazione 66251760 - V2.3 - 15/05/22...
  • Page 6: Specifiche Tecniche

    Tensione di lavoro: Fornita dalla linea BUS SEGNALI MORSETTIERA DI CONNESSIONE Ingresso campanello locale Ingresso d’allarme (non implementato) GND Massa campanello locale Contatti di collegamento al BUS - 6 - Art. 3183 - Istruzioni di installazione 66251760 - V2.3 - 15/05/22...
  • Page 7 Title: Data creazione: Foglio 22/10/2020 Titolo: Data modifica: 23/03/2021 Videx Electronics S.p.A. Notes: Autore: Roberto Gambini Via del Lavoro 1, 63846 Monte Giberto (FM) Note: Cod.File: Phone: +39 0734 631669 - Fax +39 0734 631669 23kau001e.dwg www.videx.it - info@videx.it - 7 -...
  • Page 8 - 8 - 66251760 - V2.3 - 15/05/22...
  • Page 9 - 9 - 66251760 - V2.3 - 15/05/22...
  • Page 10 - 10 - 66251760 - V2.3 - 15/05/22...
  • Page 11: Smaltimento

    DISPOSAL In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end of its lifetime, it must be collected separately from mixed municipal waste.
  • Page 12 MANUFACTURER VIDEX ELECTRONICS S.P.A. FABBRICANTE Via del Lavoro, 1 FABRICANT 63846 Monte Giberto (FM) Italy FABRICANTE Tel (+39) 0734 631669 FABRIKANT Fax (+39) 0734 632475 www.videx.it - info@videx.it FABRICANTE ‫ال� ش كة المص ن ِّ عة‬ CUSTOMER SUPPORT VIDEX ELECTRONICS S.P.A.