Installation and Maintenance Instructions
WARNING: EXPLOSION HAZARD
unless power has been switched off or unless the area is known to be non-
hazardous.
WARNING: EXPLOSION HAZARD
fuse when energized.
Failure to follow all safety precautions and instructions may result in property
damage, serious injury, or death.
With respect to the potential electrostatic charging hazard as mentioned in the
certificate "Specific Conditions of Use", under normal conditions of use, these
devices are for fixed installations and not generally in contact with people.
The risk of ignition is low. In addition, maintenance, cleaning, and extreme
environmental factors (ex. high velocity dust laden atmospheres or high pressure
steam) should be taken into account by the end user, using local Explosive
Atmosphere (Ex) Electrical installations design, selection, inspection, and
maintenance Codes and Standards. Cleaning of the devices should only be
done with a damp cloth.

Certification

Certificate Nos.:
Protection:
Gb
Gb
Standards:
6
ATEX Cert No.: Baseefa15ATEX0153X
IECEx Cert No.: IECEx BAS 15.0102X
ATEX coding:
II 2 GD Ex db op is IIC T6 Gb or II 2 GD Ex db e op is IIC T6
Ex op is tb IIIC T85°C Db IP66 (Tamb= -50°C to + 58°C)
II 2 GD Ex db op is IIC T5 Gb or II 2 GD Ex db e op is IIC T5
Ex op is tb IIIC T100°C Db IP66 (Tamb= -50°C to + 70°C)
EN60079-0: 2012 + A11:2013, EN60079-1:2014
EN60079-7: 2007, EN60079-28: 2007,
EN60079-31:2014, IEC60079-0: 6
IEC 60079-1 7
Ed.,
th
IEC 60079-7: 4
th
IEC 60079-28:2006
Model G-LED Global Series LED Beacon