Quick BX 15 Manuel De L'utilisateur page 15

Masquer les pouces Voir aussi pour BX 15:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
POS.
DESCRIPTION
1A
TANK 15L WITH HEAT EXCHANGER
1B
TANK 20L WITH HEAT EXCHANGER
1C
TANK 25L WITH HEAT EXCHANGER
1D
TANK 30L WITH HEAT EXCHANGER
1E
TANK 40L WITH HEAT EXCHANGER
1F
TANK 50L WITH HEAT EXCHANGER
1G
TANK 60L WITH HEAT EXCHANGER
1H
TANK 80L WITH HEAT EXCHANGER
1I
TANK 100L WITH HEAT EXCHANGER
2
RED PLASTIC WASHER
3
WHITE PLASTIC WASHER
4
BLUE PLASTIC WASHER
5
RELIEF/NON RETURN VALVE
6
HOSE CLAMP
7
DISCHARGE PIPE
8 A
ELEMENT GASKET
FROM S/N 100.000
8 B
ELEMENT GASKET
FROM S/N 200.000
9A
ELECTRIC ELEMENT
1200W 220V
9B
ELECTRIC ELEMENT
500W 220V
9C
ELECTRIC ELEMENT
1200W 110V
9D
ELECTRIC ELEMENT
600W 110V
10
BI-THERMOSTAT
11
POWER SUPPLY CABLE
12A
BOILER RESISTOR COVER 220V
12B
BOILER RESISTOR COVER 110V
13
NUT
14
GROUND CABLE TERMINAL
15
WASHER
16
SCREW 2,9 X 19
17A
TANK MOUNTING
BX15-BX20-BX25
17B
TANK MOUNTING
BX26-BX30-BX40
17C
TANK MOUNTING
BX41-BX50-BX60-BX80
18
BOLT
19
WASHER
20
NUT
21
CABLE CLAMP
22
SCREW 2,9 X 16
BOILER BX15-100 - REV007A
CODE
M L B 1 5 2 6 0 S 0 0 0
M L B 2 0 2 6 0 S 0 0 0
M L B 2 5 2 6 0 S 0 0 0
M L B 3 0 3 2 0 S 0 0 0
• shut down power supply.
M L B 4 0 3 2 0 S 0 0 0
• Remove the protection cover (12) in order to reach
M L B 5 0 3 6 0 S 0 0 0
the thermostat (10).
M L B 6 0 3 6 0 S 0 0 0
• Push the reset button on the double thermostat (fig. 4).
M L B 8 0 3 6 0 S 0 0 0
• Replace on the protection cover (12).
M L B 1 0 0 3 6 0 S 0 0
• Switch on power supply.
P E C R B L R S 0 0 0 0
P E C R B L B N C 0 0 0
P E C R B L B L 0 0 0 0
M N VA L S 1 2 S 6 8 P
P B F 2 5 1 0 0 W 0 0 0
P V T B G M 1 0 N T 0 0
MAINTENANCE
P G G R E S 0 0 0 0 0 0
We recommend checking the magnesium anode (A) every
P G R M 4 3 5 0 0 0 0 0
12 months.
E V R 1 2 2 2 0 N 0 0 0
Replace the anode if its size has been reduced significantly.
This simple and preventive maintenance will ensure a long
E V R 0 5 2 2 0 N 0 0 0
life of the equipment.
E V R 1 2 1 1 0 N 0 0 0
F
E V R 0 6 1 1 0 N 0 0 0
E V T 1 5 S 0 0 0 0 0 0
E C C 3 0 1 5 0 G 0 0 0
P E C R B 2 2 0 0 0 0 0
P E C R B 1 1 0 0 0 0 0
The overpressure release device must be activated regular-
MBD04MXEN000
ly to remove calcium deposits and to ensure that it is not
E J C Y 0 4 0 0 0 0 0 0
blocked.
M B R 0 4 X 0 0 0 0 0 0
MBV02919AXCC
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
M M S T B L 3 0 0 D R 1
them in case they are worn or corroded.
M M S T B L 4 0 0 D R 1
Also periodically check the electrical system working order.
M M S T B L 4 0 0 D R 1
MBV0830MXE00
M B R 0 8 X 0 0 0 0 0 0
MBD08MXEN000
P P B L B X 0 0 0 0 0 0
MBV02916AXCC
MAINTENANCE
WARNING:
Quick
nautic water heaters are provided
®
with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
if the high temperature safety system
WARNING:
switches on repeatedly, call Quick
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (5). This is to avoid serious damage caused
by freezing.
EN
service center.
®
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bx 20Bx 25Bx 30Bx 40Bx 50Bx 60 ... Afficher tout

Table des Matières