CONTROLS
|
The controls are positioned on the front of the
unit next to the air outlet, they are:
• Power Switch
• Ammeter
• Hour Meter
• Remote Humidistat Switch
• Remote Humidistat Connector
TROUBLESHOOTING
|
If the dehumidifier does not operate:
• Make sure the unit is plugged in.
• Check the fuse
• Check the remote humidistat setting
• Ensure the humidistat (if fitted) is turned on
Low Airflow:
• Check inlet air filter
• Check inlet/outlets not obstructed
• Check ductwork (if fitted) is not obstructed
• Check voltage level
• Check fan is working
If the unit is noisy:
• Check fan operation
• Check rotor drive
• Check for loose screws
EPD150 EPD150-PRO
A
REMOTE HUMIDISTAT
POWER
OFF
OFF
ON
ON
Low Dehumidifying Effect:
• Check airflows
• Check Amps reading
• Check rotor is turning
Low Amps Reading:
• Check Regen airflow
• Check Over-Heat Protector
• Check Heater bank
Rotor Not Turning
• Check belt tension
• Check drive-motor operation
• Check rotor alignment
EPD200 EPD200-PRO
A
10
5
OFF
OFF
O
O
Remote
POWER
Humidistat
I
I
ON
ON
US