Safety Lock-Out; Shut-Down Instructions; Cleaning Instructions - L.B. White Foreman CI500 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

18
Foreman Ductable Dual Fuel Indirect-Fired Heater

Safety Lock-Out

This heater is equipped with interlocking safety
devices. In the event of a failure while the burner is
in operation, or if the burner air supply is obstructed,
the burner will "lock-out". If this happens, the reset
button on the burner controller will illuminate to
RED.
TO RESET THE CONTROL BOX
Push and hold the reset button on the burner
controller for 1 to 2 seconds.
The burner will restart after a 1 second pause once
the button is released.
DIAGNOSTICS MODE
The controller features diagnostics which identifi es
the cause of malfunction in the heater.
To use the feature, wait at least 10 seconds once
the heater has entered lock-out mode (steady RED
light). Press and hold the reset button for more
than 3 seconds or until a yellow light pulses to
inform you the operation is completed. Release the
button and a red light will pulse a number of times
to identify the malfunction that occurred. Refer to
the troubleshooting section for further information.
■ The controller has only one ignition trial. If igni-
tion is not achieved, the ignition burner control
will enter "lock-out" mode.
■ It is normal for air to be trapped in gas hose on
new installations. The heater may require several
trials for ignition before air is fi nally purged from
line and ignition takes place.
Owner's Manual • Foreman

Shut-Down Instructions

If the heater is to be shut down for cleaning, mainte-
nance, or repair, follow steps 1-6. Otherwise, simply
adjust thermostat to "Off" or "No Heat" or T stat
switch for thermostat only for standard shut-down.
1. Close the gas supply valve located on the gas
supply container / sources.
2. Allow the heater to burn off any fuel gas remain-
ing in the gas supply line.
3. Set the thermostat to "Off" or the selector switch
to the midpoint position O.
4. Allow heater to perform it post purge cool down
Reset
mode. SEE NOTE BELOW
Button
5. Disconnect the heater from its gas and electrical
supplies. (DO NOT DISCONNECT THE ELECTRI-
CAL SUPPLY UNTIL THE MAIN FAN MOTOR
HAS CYCLED OFF FROM COOLING THE HEAT
EXCHANGER)
Note: When either the thermostat cycles the heater
off or the selector switch is in the OFF position, the
main fan motor will continue to operate. This is the
cool down post purge of the heat exchanger. During
this process the LED fl ashes after 90 seconds of
post purge, the heater will shut-off.

Cleaning Instructions

Fire, Burn, and Explosion Hazard
■ This heater contains electrical and mechani-
cal components in the gas management, and
safety systems.
■ Such components may become inoperative
or fail due to dust, dirt, wear and aging.
■ Periodic cleaning and inspection as well as
proper maintenance are essential to avoid
serious injury or property damage.
1. Before cleaning, shut off all gas supply valves and
disconnect electrical supply.
2. The heater should have dirt or dust removed
periodically:
WARNING

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Foreman ci750

Table des Matières