Attaching The Mounting Plate - Haiku K3150-S1 Guide D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The ceiling-mounted outlet box must be UL-listed and marked "Suitable for Fan Support." If
!
your existing outlet box is not UL-listed, it must be replaced with one that is UL-listed.
Step 4. Attaching the mounting plate
Ensure wiring has been routed to the fan site.
Secure the mounting plate to the outlet box with the hardware
supplied with the outlet box.
Make sure to mount the plate in the correct mounting
!
holes on the outlet box!
Step 5. Securing the safety cable
Attach one mounting bracket to the mounting plate, but do not fully tighten. Raise the fan to the
mounting bracket and temporarily rest one rubber bumper in the space between the bracket and
plate to help support the fan while securing the safety cable.
Loop the safety cable around the mounting plate, and then secure it with the locking pin. Allow the
fan to hang from the safety cable. This ensures there is enough slack and allows space to perform the
wiring.
Special Note: If you are installing the fan in Canada, the
safety cable must be secured to an existing part of the building
structure instead of the outlet box. Examples of acceptable
building structures include a wooden beam or a metal mounting
brace secured between two beams. In some cases it may be
necessary to install additional structural material to provide
attachment points. If you have concerns about installing the
safety cable, consult a structural engineer.
HAIKU by Big Ass Fans
INSTALLATION (CONT.)
Safety
cable
Mounting
plate
Mounting
bracket
7

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

S3150-s1

Table des Matières