4

Adjust date and time

LANG:
Language selection
Selection:
dE, En, It, Fr, Es
Factory setting: En
Adjustment channel for the menu language.
• dE : German
• En : English
• It : Italian
• Fr : French
• Es : Spanish
In order to adjust the menu language, carry out the
following steps:
Î Scroll down in the display menu and press button
2 for approx. 3 seconds after you have reached
the last display item.
Î Select the LANG channel using button 2 and the
press button 3
Î Adjust the language by pressing buttons 1 and 2
Î Press button 3 to confirm
TIME
Time:
Shows the current
time
Î In order to adjust the hours press button 3 for
two seconds
Î Adjust the hours by pressing buttons 1 and 2
Î In order to adjust the minutes press button 3
Î Adjust the minutes by pressing buttons 1 and 2
Î In order to save the adjustment press button 3
14
14
5

Display values

5.1

Display channels

Channel Description
COL
Temperature collector
TST
Temperature store base
TSTT
Temperature store top
h P1
Operating hours relay 1
h P2
Operating hours relay 2
kWh
heat quantity kWh
MWh
heat quantity MWh
TIME
Time
Display of collector temperature
COL:
Collector temperature
Display range:
-40...+260 °C
-40 ... +500 [°F]
Shows the current collector temperature.
• COL : Collector temperature
Display of store temperature at the bottom
TST:
Store temperature
Display range:
-40...+260 °C
-40 ... +500 [°F]
Shows the current store temperature.
• TST : Temperature store base
Display of store temperature at the top
TSTT
:
Temperature store top
Display range:
-40...+260 °C
-40 ... +500 [°F]
Shows the current store temperature at the top.
• TSTT : Temperature store top

Operating hours counter

h P1 / h P2:
Operating hours counter
Display channel
The operating hours counter accumulates the solar
operating hours (h P1) and the operating hours of
the afterheating (h P2) respectively. Full hours are
displayed.
The accumulated operating hours value can be set
back to 0. As soon as one operating hours channel is
selected, the
symbol is displayed.
Î In order to access the RESET-mode of the coun-
ter, press the SET (3) button for approx. two sec-
onds.
Î The display symbol
will flash and the operat-
ing hours will be set to 0.
Î Confirm the reset with the SET button in order
to finish the reset.
In order to interrupt the RESET-process, do not press
a button for about five seconds. The display returns to
the display mode.

Publicité