CLEARANCES

As viewed from
the front of heater,
these are the minimum
clearances from cabinet
to combustible
construction:
• In selecting a location for installation it is necessary to
provide adequate accessibility clearances for servicing
and proper operation.
• This appliance must not be connected to a chimney flue
that serves to vent a solid-fuel burning (wood or coal)
appliance, or a multi-vent system.
BE SURE TO LEAVE ENOUGH ROOM
ON ONE SIDE OF THE HEATER FOR THE
COVER AND MOUNTING PLATE PLACEMENT
Removal of the cover requires at least 10" of space
from the heater housing to the side wall.
CEILIN G
Top of
heater
housin g
A t le a s t 2 "
b o tt o m
o f h e a te r
h o u s in g
F L O O R
Side Wall - 1"
without Pilot Pro Cover
Side Wall - 10"
with Pilot Pro Cover
Floor - 2"
Ceiling - 11"
At
least 10"
with Pilot
Pro Cover
Page 5
CONTROLS
All controls are preassembled at the factory.
The normal manifold pressure should be 3.5" w.c. on Natural
Gas. The maximum inlet pressure in the gas supply pipe
should never exceed 7.0" w.c. on Natural Gas.
The appliance and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psig.
The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig.
The minimum inlet pressure in the gas supply pipe should be
5.0" w.c. on Natural Gas "for purpose of input adjustment".
The appliance is orificed at the factory for elevations between
sea level and 2,000 feet. If installed above 2,000 feet, the BTU
input must be reduced 4% per 1,000 feet that the furnace is
above sea level. See the following orifice chart for the proper
orifice for a specific elevation. The orifice(s) will have to be
drilled to correct size by a qualified installer, service technician
or the gas supplier.
Model
0' -
No.
2,000'
W255GPPR
43
W255GPPD
43
W355GPPR
36
W355GPPD
36
ORDER KIT #49820 45-1 High Altitude Kit
Model
0' -
No.
2,000'
W505GPPR
43
W505GPPD
43
ORDER KIT #49850 2287-2 High Altitude Kit
ORIFICES
2,000' -
4,000' -
6,000' -
4,000'
6,000'
8,000'
44
45
47
44
45
47
38
40
41
38
40
41
2,000' -
4,000' -
6,000' -
4,000'
6,000'
8,000'
44
45
47
44
45
47
8,000' -
10,000'
48
48
43
43
8,000' -
10,000'
48
48
1018454-E