STEP 1.
Turn on all gas and electricity to the appliance.
Conduct a gas leakage test of the appliance piping & control
system downstream of the shutoff valve in the supply line to
the appliance.
STEP 2.
!
Adjust thermostat to lowest setting.
Place two D Batteries (46) in the Battery pack (28).
2a.
Initial startup of the pilot pro system may take
several minutes due to air in the PILOT gas line.
2b. After turning up thermostat, the ignitor will
begin to spark. After 1 minute, it will stop.
2c. IF PILOT DOES NOT LIGHT:
Lower thermostat to OFF, then turn it back up.
2d. Ignitor will start to spark.
2e.
Repeat steps 2b through 2d until the pilot lights.
2f.
Visually determine that main burner is burning
properly (i.e., Flame isn't too soft or too hard).
To adjust the primary air shutter(s) as required,
see flame adjustments on page 25.