Monitoring And Configuration Dip Switch; Emergency Operation - Daikin Altherma EHS04P30B Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 164
8
x
Errors, malfunctions and messages
Fig. 8-4
Components in the heat pump circuit (simplified diagram)
a
Plate heat exchanger (condensator)
b
Ventilator motor
c
Lamella heat exchanger (evaporator)
e
Filter
f
Electronic expansion valve
g
Service valve (liquid line)
h
Service valve with maintenance connection (gas line)
i
Accumulator
k
Coolant compressor
n
4-way diverter valve (—> Heat, ····> Cool)
o
Inverter board
R1T
External temperature sensor
R2T
Discharge temperature sensor (coolant compressor)
R3T*
Suction temperature sensor (coolant compressor)
R4T*
Temperature sensor lamella heat exchanger-input
R5T
Temperature sensor lamella heat exchanger-middle
R6T*
Temperature sensor liquid line (t
R10T*
Temperature sensor on inverter board
S1PH
High pressure switch
S1NPH
Pressure sensor
*
Only with 11-16 kW heat pump external devices.
Tab. 8-3 Legend for fig. 8-4

8.4 Monitoring and configuration DIP Switch

WARNING!
Touching live parts can result in an
electric shock and lead to potentially
fatal injuries and burns.
Before beginning work on live parts,
disconnect all of the systems circuits
from the power supply (switch off
main switch, disconnect fuse) and
secure against unintentional restart.
Means with contact separation in all
poles that provide full disconnection
must be incorporated in the fixed
wiring in accordance with the wiring
rules.
Installation and operating instructions
66
)
L2
Fig. 8-5
*
Tab. 8-4 DIP switch settings

8.5 Emergency operation

In the case of incorrect setting in the electronic control system,
emergency heating operation can be maintained by activating the
special "Manual Operation" function on the control unit (see op-
erating manual for the control unit).
If the 3-way valves are intact, the Daikin Altherma EHS(X/H)
switches to Heating mode. The necessary flow temperature can
be adjusted with the rotary switch.
Disconnect the system from the power supply.
Open the control housing and remove the RoCon BM1 board
(see chapter 4.5.7).
Check the DIP switch setting on the A1P circuit board of the
Daikin Altherma EHS(X/H), adjust where necessary
(see tab. 8-4).
The factory preset may only be changed if e.g. an
optional accessory was connected.
Replace the RoCon BM1 switch board, close the control
housing and reconnect the power supply.
DIP switch settings are not recognised until a brief inter-
ruption to the power supply.
Setting of DIP switch SS2
No.
Designation
DIP
switch
1
Do not change.
Domestic hot water gener-
2
SS2
3
Pump continuous running*
4
Do not change.
If you intend to run the internal heating circulation pump continuously, it will
need to be connected to the circuit board A1P, plug X17A, via a separate con-
nection cable (
E1400132).
Factory setting
OFF
ON
ation
OFF
OFF
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN