Panic bar PS160XA/PS111XA
Important information
Item numbers
PS160XA10, PS160XA20, PS111XA10, PS111XA20
28
Outer dimension
14
Centre-to-centre measurement
Center-to-center (BA)
Customer specification
extendable from
extendable from
extendable from
extendable from
extendable from
extendable from
Item numbers
PS160XA30, PS160XA40, PS111XA30, PS111XA40
31
Outer dimension
15,5
Centre-to-centre measurement
70
Center-to-center (BA)
Customer specification
extendable from
extendable from
extendable from
extendable from
extendable from
extendable from
8 | HEWI
14
99
14
761 to
860 mm
861 to
1010 mm
1011 to
1160 mm
1161 to
1300 mm
1301 to
1440 mm
1441 to
1580 mm
BKS
22,5
99
15,5
70
766 to
865 mm
866 to
1015 mm
1016 to
1165 mm
1166 to
1305 mm
1306 to
1445 mm
1446 to
1585 mm
Proper use
HEWI panic bar for doors with panic device according
to DIN EN 1125.
Panic devices enable safe escape through doors with
little effort, without requiring prior knowledge on how
to operate the panic device. Panic devices are used in
public buildings and places used by the public.
A horizontally attached bar enables the door to be easily
opened even in the dark or smoke.

Mounting information

The safety characteristics of this product are essential
for compliance with DIN EN 1125. With the exception of
the changes described in these instructions, no other
modifications whatsoever may be made.
A panic device according to DIN EN 1125 is made up of:
A Panic bar
B Lock system; depending on the application, consis-
ting of:
Lock, locking bars, locking plate, lock recesses, etc.
These installation instructions solely refer to the moun-
ting of the panic bar listed under A.
The separate installation instructions for the lock system
according to B must be carefully read and followed.
The doors must be in a technically perfect condition
when the devices are fitted and the doors must be che-
cked to ensure easy movement.
When mounting the devices on fire doors and smoke
control doors the relevant standards and the door ma-
nufacturer's instructions must be read and followed.