The Lifebreath Ventilation Control 99-BC03
The Lifebreath Ventilation Control offers advanced features to control your home's ventilation.
Key Features:
Continuous LOW fan speed operation
Electronic Dehumidistat
3 modes of operation:
Ventilation
Recirculation
20/40 mode
Compatible with 99-DET02 Wireless Timers
Slim-line design
Connect to 3 wire 20 gauge low voltage
wire
BC03 Operating Instructions:
Turning on the Control
Press and release the ON/OFF button
above will illuminate and the fan will turn on to
LOW speed.
Humidity Control
Your unit will reduce indoor humidity when outdoor humidity levels are lower than indoor humidity levels.
This feature is only effective when the outdoor temperature is below 59˚F (15˚C).
Setting the Dehumidistat
Press and release the Dehumidistat button
seconds the Dehumidistat light will either flash or be on continuous.
A flashing light indicates the humidity level is higher than the setting and the unit is operating on high speed
ventilation. A continuous light indicates the humidity level is lower than the setting. Refer to the unit's Home
Owner's manual for instructions on how the Dehumidistat works.
The Dehumidistat will override the current fan speed setting to high fan speed.
The Dehumidistat function can be turned OFF by pressing the
Note - Only 1 Dehumidistat should be installed in a system.
Setting 20/40 Mode
To activate 20/40 mode, press and release the Mode button
illuminated.
20/40 mode is a repeating cycle. The fan will run at LOW speed for 20 minutes, then turn OFF for 40 minutes.
Some units are equipped to Recirculate air in your home during the 40 minute cycle with no Ventilation. The
control will automatically detect this feature and Recirculate air during the 40 minute cycle at LOW fan speed.
Recirculation Mode
Some units are equipped to Recirculate the air in your home without Ventilating.
To activate Recirculation mode, press and release the Mode button
Light" in ON. Recirculation is in LOW fan speed.
ATTENTION
Only one main control can be installed on your system.
Recirculation is not available on all models.
Timers will not function when mode of operation is set to "OFF", unless specifically installed for that function. (See
Installation Guide for other options.)
Humidity
Setting
LOW Fan Speed
Indicator Light
ON/OFF Button
Dehumidistat
Button
. The light
until the Dehumidistat Light is at the desired setting. After a few
button until no Dehumidistat light is on.
until the "Indicator Light" below 20/40 is
until the Recirculation
20/40 Mode
Indicator
Recirculation
Mode Indicator
Mode Button
"Indicator