Maintenance Routine - Airia Lifebreath RNC5-ES Guide Du Propriétaire

Table des Matières

Publicité

Maintenance Routine

1. Inspect Exterior Hoods at Least Once a Month
Make sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass,
or snow. In winter, it is especially important to make sure snow is not blocking the hoods or
that frost has not built up on the wire mesh (bird screen).
2. Clean Air Filters (Clean Four times a Year)
The standard filters equipped with your HRV are removable and washable.
a) Open access door and slide core out.
b) Remove filter clips if present.
c) Once clips are removed, filters can be taken off the core to be rinsed with water or a
combination of mild soap and water. Do not clean in the dishwasher.
d) To re-assemble, place clean filter(s) (wet or dry) back into their positions against the core
and return clips to their original positions.
e) Slide core back into its original position.
3. Clean Core Twice a Year
a) Open access door.
b) Carefully grip ends of core and pull evenly outward. Core may be snug, but will slide out
of the cabinet.
c) Once removed from the cabinet remove filters.
d) Install the clean filters.
e) Install clean core in the cabinet.
Note: Core installation label on the outer end of the core.
To Install the Clean Core:
a) To reinstall the core first position the bottom of the core on the bottom support in the
cabinet.
b) Carefully align the core with the other 3 supports and fully insert the core.
c) Push on sides of core, do not push on the center.
Note: Core may appear to stick out from the cabinet approximately 1/8 in (3 mm). This is
designed this way so that the access door will fit tight against the core.
Attention/Warning
Do not use cleaning solutions for the HRV core
Soak and rinse the HRV core in warm soapy water
Do not use bleach or chlorine
Do not use a pressure washer on the HRV core
Do not place the HRV core in a dishwasher
Warning:
Electric shock hazard. Can cause injury or death. Before attempting to perform any service or maintenance, turn
the electrical power unit off at disconnect switch(es). Unit may have multiple power supplies.
Blockage of hoods may cause an imbalance