Electrical connections
ELECTRICAL
CONNECTION TO
FURNACE
FOR A FURNACE
CONNECTION TO
A COOLING SYSTEM:
On some older thermostats, energizing
the R and G terminals at the furnace
has the effect of energizing Y at the
thermostat and thereby turning on
the cooling system. If you identify this
type of thermostat, you must use the
"Alternate Furnace Interlock Wiring".
NEVER CONNECT A 120 VOLT AC CIRCUIT TO THE TERMINALS OF THE ACCESSORY CONTROL CONTACTS. ONLY USE
THE LOW VOLTAGE CLASS 2 CIRCUIT OF THE FURNACE BLOWER CONTROL.
(cont'd)
Standard Accessory Control Contact
Standard Furnace Interlock Wiring
W
FOUR
WIRE
TWO WIRE
heating only
W
R
G
C
Y
FURNACE
24-VOLT
TERMINAL BLOCK
Alternative Accessory Control Contact
Alternate Furnace Interlock Wiring
W
FOUR
WIRE
TWO WIRE
heating only
W
R
WIRE JOINT
G
C
Y
FURNACE
24-VOLT
TERMINAL BLOCK
THERMOSTAT
TERMINALS
R
G
Y
TWO
WIRE
THERMOSTAT
TERMINALS
R
G
Y
TWO
WIRE
17
COOLING SYSTEM
COOLING SYSTEM