2.3
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
Altitude (FT)
Max. Input (BTU/HR)
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under
Flow Conditions)
B36NTR
B36NTRE
B36PTR
B36PTRE
GX36NTR
GX36NTRE
GX36PTR
GX36PTRE
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for
mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
QUALITY!
RATES AND EFFICIENCIES
B36
NG
0-4,500
0-4500
18,000
18,000
4.5" (11mb) w.c.
11" (27mb) w.c.
13" (32mb) w.c.
13" (32mb) w.c.
3.5" (9mb) w.c.
10" (25mb) w.c.
MODEL DESIGNATIONS
FUEL TYPE
NATURAL
NATURAL
PROPANE
PROPANE
NATURAL
NATURAL
PROPANE
PROPANE
LP
NG
0-4,500
26,000
4.5" (11mb)
w.c.
13" (17mb) w.c.
3.5" (9mb) w.c.
OPERATING SYSTEM
ELECTRONIC IGNITION
ELECTRONIC IGNITION
ELECTRONIC IGNITION
ELECTRONIC IGNITION
7
GX36
LP
0-4,500
26,000
11" (27mb) w.c.
13" (32mb) w.c.
10" (25mb) w.c.
MILLIVOLT
MILLIVOLT
MILLIVOLT
MILLIVOLT
W415-1401 / D / 05.25.16
EN