Minimum clearance to combustible construction from appliance and vent surfaces:
Combustible Framing:
EN
-
-
-
Combustible Finishing:
-
-
Top Exit
-
-
Rear Exit
-
-
*B36 HORIZONTAL VENT SECTIONS: A minimum of 1" (25mm) at the bottom and sides and 3" (76mm) at
the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-3440
(supplied).
NOTE: The minimum clearances from the top of the horizontal vent pipe to combustible materials may
be reduced from 3" (76mm) to 1" (25mm) in those installations with a minimum 38" (965mm) vertical
vent rise made immediately off the fi replace collar.
*B36 VERTICAL VENT SECTIONS: A minimum of 1" (25mm) all around the vent pipe on all vertical runs
to combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).
33 7/8"
860mm
W415-1401 / D / 05.25.16
0" to stand-offs
1" (25mm) to bottom and sides of the vent pipe*
3" (76mm) to top of the vent pipe*
0" to rear stand offs
0" to front face top and sides
50 1/2" (1283mm) to combustible enclosure top from base of the appliance
54" (1372mm) to ceiling from base of the appliance
41" (1041mm) to combustile enclosure top from base of the appliance
54" (1372mm) to ceiling from base of the appliance
OUTSIDE
CHASE
35 1/2" 902mm
16"
406mm
35 1/2" 902mm
16"
406mm
INSIDE
CHASE
SIDE
WALL
2" 51mm