Leyco IQsoft IQ-CS Instructions D'installation & Emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
To cancel this mode, press the scroll
repeatedly; the control panel will return to the service
mode.
SALT LEVEL ALARM
The electronic control panel is equipped with a salt level
alarm, that will periodically remind the user to check the salt
level inside the brine cabinet and to refill it with water
conditioner salt if necessary. When the salt level alarm is
triggered, the following will happen:
1. the backlight of the display will flash on/off;
2. the buzzer, if enabled (see Basic Settings), will beep 3
times every 5 minutes;
3. the display will show:
Check salt level
To reset push
After refilling the brine cabinet, simply push the down
button to reset the salt level alarm. If any other button is
pushed, the salt level alarm will be cancelled, but not reset,
meaning it will be activated again after the next regeneration!
If the brine cabinet is refilled by the user with water
conditioner salt, before the salt level alarm is activated, it is
possible to reset the salt level alarm.
1. Press the scroll
button; the display will show:
Salt Added?
To reset push
Press the down
button to reset the salt level alarm.
HOLIDAY MODE
It is possible to put the appliance in holiday mode; this will
prevent automatic regeneration from taking place, yet will
ensure the appliance is automatically regenerated at the end
of the holiday cycle.
1. Press the scroll
button repeatedly until the display
shows:
Holiday: OFF
Press the up
or down
holiday mode by setting the number of full days away
from home, or deactivate the holiday mode (OFF).
Once the control panel is back in service mode, the display
will show:
8:01
Holiday
TotVol: 1234567L
The holiday mode is automatically cancelled when a
regeneration is manually initiated!
ELECTRONIC CONTROL PANEL
button
button to activate the
Page 9
PROGRAMMING INSTRUCTIONS -
BASIC SETTINGS
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
button and hold it for 2 sec until the
display shows:
Language:English
Press the up
or down
language.
2. Press the scroll
button again; the display will show:
Set time:
Press the up
or down
day.
3. Press the scroll
button again; the display will show:
HardUnit:
Press the up
or down
measure for water hardness. Make sure it is identical
to the unit of measure of the water hardness test kit
or water analysis report that is used to determine the
hardness of the incoming untreated water!
4. Press the scroll
button again; the display will show:
Set hardn: XX °f
Press the up
or down
of the incoming untreated water.
5. Press the scroll
button again; the display will show:
Buzzer: 2
Press the up
or down
buzzer by setting the sound level, or disable the buzzer
(OFF).
6.
Press the scroll
button again; the display will show:
Exit
Press the up
or down
into the NOVRAM® and exit the programming mode.
button to set the
8:01
button to set the time of
°f
button to set the unit of
button to set the hardness
button to enable the
button to save the settings
EN - English

Publicité

Table des Matières
loading

Table des Matières