SYMPTOM
Continues to spark
EN
and pilot lights, but
main burner will not
light.
Pilot lights
Stops sparking
/ pilot remains lit
but burner will
not turn on.
Exhaust fumes
smelled in room,
headaches.
White / grey fi lm
forms.
Flames are very
aggressive.
Main burner fl ame
is a blue, lazy,
transparent
fl ame.
Main burner goes
out: pilot goes out.
W415-1519 / H / 03.22.17
PROBLEM
Short or loose
connection in sensor rod.
Poor fl ame rectifi cation
or contaminated
sensor rod.
Poor grounding between
pilot assembly and
gas valve.
Damaged pilot or dirty
sensor rod.
Wiring / Connection.
Wiring harness.
Appliance is spilling.
Sulphur from fuel is being
deposited on glass, logs or
combustion chamber
surfaces.
Door is ajar.
Venting action is too great.
Blockage in vent.
Compromised venting.
Vent recirculation.
TEST SOLUTION
Verify all connections. Verify the connections from the
-
pilot assembly are tight; also verify these connections are
not grounding out to any metal.
Verify the fl ame is engulfi ng the sensor rod. This will
-
increase the fl ame rectifi cation. Verify correct pilot orifi ce is
installed and inlet gas specifi cations to manual. (Remember,
the fl ame carries the rectifi cation current, not the gas. If the
fl ame lifts from pilot hood, the circuit is broken. A wrong
orifi ce or to high of an inlet pressure can cause the pilot
fl ame to lift.) The sensor rod may need cleaning.
Verify that the wire harness is fi rmly connected to module.
-
Verify that the ceramic insulator around the sensor rod is
not cracked, damaged, or loose. Verify the connection from
the sensor rod to the sensor wire.
Clean sensor rod with a fi ne emery cloth or synthetic
-
scrub pad to remove any contamination that may have
accumulated on the sensor rod. Verify continuity with
multimeter with ohms set at the lowest range.
Inspect all wires, ensure good tight connections. Verify
-
that all wiring is installed exactly as specifi ed.
Inspect the wiring harness, and verify the harness is
-
tightly connected to the module. Verify that all wires are
connected in the right order. See "WIRING DIAGRAM"
section.
Check all seals.
-
Check if exhaust is re-entering through an open door or
-
window.
Clean the glass, see "CARE OF GLASS" section
-
DO NOT CLEAN GLASS WHEN HOT.
-
If deposits are not cleaned off regularly, the glass may
-
become permanently marked.
Tighten door clamps if applicable.
-
Restrict vent exit with restrictor plate. See
-
"RESTRICTING VENTS" section if applicable.
Remove blockage. In extreme conditions, ice buildup
-
may occur on the terminal and should be removed. To
minimize this from happening again, it is recommended
that the vent lengths that pass through unheated
spaces (attics, garages, crawl spaces) be wrapped
with an insulated mylar sleeve. Prevent sleeve from
sagging. Contact your local authorized dealer for more
information.
Check venting system parameters (seal, length, rise, etc.).
-
Check joint seals and installation.
-