Napoleon GX70NTE Instructions D'installation Et D'utilisation page 26

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

26
It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building
codes.
EN
It is not necessary to install a hearth extension with this appliance.
When roughing in the appliance, raise the appliance to accommodate for the thickness of the finished floor
materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower
access door and the installation of many decorative flashing accessories.
Non-Combustible material (brick,stone or ceramic tile) may protrude over the black areas of the appliance.
Maintain these minimum clearances to combustibles from appliance and vent surfaces:
Appliance framing:
Non- Combustible Appliance finishing:
Front -
-
Combustible Appliance finishing:
-
-
-
Non-combustible finishing material (ie. cement board, brick, stone, tile) must be used to finish the front of
the appliance.
* HORIZONTAL VENT SECTIONS: A minimum of 2" (51mm) at the bottom and sides and 3" (76mm) at
the top of the vent pipe on all horizontal runs to combustibles is required. Use firestop spacer W010-1800
(supplied).
* VERTICAL VENT SECTIONS: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use firestop spacer W500-0096 (not supplied).
33 7/8"
86cm
W415-1519 / H / 03.22.17
3" (76mm) to sides of appliance opening
6 3/4" (171.5mm) above appliance opening
59 1/2" (151.1cm) from bottom of appliance to enclosure top
3" (76mm) to top of vent pipe*
2" (51mm) to sides and bottom of vent pipe*
OUTSIDE
CHASE
35 1/2" 90.2cm
18 9/16"
47cm
35 1/2" 90.2cm
18 9/16"
47cm
INSIDE
CHASE
SIDE
WALL
152.4mm
6"

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Gx70pte

Table des Matières