Electrical Data; Installation Safety Instructions - Field Controls SWG-AF Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
The SWG-AF series power vents are designed for sidewall venting of a single listed automatic feed Corn,
Wood Pellet and other Bio-fuel burning heating appliances.
1. The power vent operates continuously while the heating appliance is in operation. After the mechanical
draft vent motor has come up to speed, the pressure switch closes. This closes the circuit to the burner
feed circuit and allows the burner to fire.
2. A barometric draft control is required to maintain the proper draft through the appliance. It also
regulates the appliance venting under extreme changes in windy weather conditions.
3. A pressure sensing switch and blocked vent safety switch are wired into the burner feed circuit. If
proper venting is not maintained, one or both switches will open and the burner feed circuit will de-
activate.
TO THE USER
For continued safe operation, the heating appliance MUST be cleaned and inspected annually by a qualified
service agency. It is recommended that the owner operator should have the appliance and power vent system
examined annually for deterioration from corrosion or other sources. The inspection should be performed prior
to each heating season.

ELECTRICAL DATA

Power Vent Operating Current:
Maximum Pressure Switch Current:
Maximum Blocked Vent Switch Current:

INSTALLATION SAFETY INSTRUCTIONS

WARNING: The SWG-AF power vent system must be installed by a qualified agency.
The definition of a qualified agency is: ".. any individual, firm, corporation, or company who either in person or through a
representative is engaged in, and is responsible for installation and operation of solid or bio-fuel heating appliances. Who
is experienced in such work, familiar with all the precautions required, and has complied with the requirements of the
authority having jurisdiction".
CAUTION
The Field Controls DIP-1 pressure switch, Barometric Draft Control and WMO-1 blocked vent switch must
be properly installed and interlocked to the appliance burner feed circuit. See the appliance manufacturer's installation
instructions for proper wiring. The power vent and draft equipment is only for use as a venting option for specific listed
automatic fuel-burning appliances; refer to the appliance manufacturer's instructions for proper application and installation.
The installer must write or imprint his name, phone number and date of installation on the installation tag.
The tag should be attached to the power venting unit.
Recording burner and venting system initial operational information is strongly recommended as a guide for
service or burner tune-up. Enter recorded information on the back page of this manual.
1. Safety inspection of a venting system must be performed before and after installing a power venting system on an
existing or new appliance. Procedures to follow are those recommended latest version of:
In the USA
NFPA 211 Standard for Fireplaces, Vents and Solid Fuel-Burning Appliances, The International Mechanical
Code and / or International Residential Code or refer to the General Installation Inspection section of this
manual.
In Canada
CSA B 365 Installation Code for Solid Fuel-Burning Appliances and Equipment
2. Plan the vent system layout before installation to avoid the possibility of accidental contact with concealed wiring,
plumbing inside walls and combustible materials.
SWG-4AF/5AF: 1.77A @ 115V and SWG-6AF: 1.3A @ 115V