2.4 Pin assignment of the field bus connection
(open style, screw terminals, IP20):
Open style connection
1
2
3
4
5
Order one of the following connections from Festo for the
field bus:
micro style: type FBA-2-M12-5pol
open style: type FBA-1-SL-5pol
with terminal strip: FBSD-KL-2x5pol.
Please note
If you wish to fit the CPV Direct type CPV..-GE-DN2-8
into an existing system as a replacement for a CPV
Direct type CPV..-GE-DN-8:
S Modify the wiring of the load voltage supply.
S Adapt the configuration in your configuration
software.
Details see manual P.BE-CP-DN2-.. .
16
Pin no.
1. 0 V Bus
2. CAN_L
3. Screening/shield
4. CAN_H
5. 24 V DC bus (max. 4 A)
Terminal strip
Festo CPV..-GE-DN2-8 0107NH English