Manufacturer (Cos) / Configuration (Cfn); Branch Table Of Parameters - AERMEC SWP200 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

12.4.
MANUFACTURER (COS)
/ CONFIGURATION
(CFN) BRANCH TABLE OF
PARAMETERS
PARAMETER
H01
H02
H03
H04
H05
H06
H07
H08
H09
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
H20
H21
H22
H23
H24
H25
H26
H27
H28
H29
H30
H31
H32
H33
H34
H35
H36
54
SWP_5287500_00
DEFAULT
LIMITS
60
H02-60
30
30-H01
15
H04-30
0
-15
8
H04-H03
5
0-15
65
H01-70
365
1-365
3
01-05
15
15-30
24
6-24
1
0-01
1
0-01
0
0-01
0
0
0
0
0
0-01
0
0-255
0
0-01
90
0-255
100
0-255
30
0-255
1
0-1
40
35-100
100
H24-100
3
0 -15
60
H02-70
3
0-15
1
0-1
0
0-1
0
0-1
1
0-1
1
0-1
1
0.5-2
20
15-25
10
5-10
UNIT
DESCRIPTION
°C
Max. boiler water set point value achievable with
HP
°C
Min. boiler water set point value
°C
Max. outside air set point
°C
Min. outside air set point
°C
Outside air set point for heating element activation
H06 5
°C
Heating element deactivation differential
°C
Thermal shock set point
days
Anti-bacterial treatment cycle frequency
Num(1)
Number of cycles per individual anti-bacterial
treatment
min
Duration of each cycle (time during which the
thermal shock temperature is maintained)
hrs
Interval between two consecutive cycles
Num(1)
Confi gure the polarity of digital input ID1 [1=active if
the contact is open]
Num(1)
Confi gure the polarity of digital input ID2 [1=active if
the contact is open]
Num(1)
Confi gure the polarity of digital input ID3 [1=active if
the contact is open]
°C
S1 probe offset (input AI1)
°C
S2 probe offset (input AI2)
Num(1)
Establish the mains power frequency [0=50 Hz]
Num(3)
Manufacturer password (for accessing level 2
parameters)
Num(1)
Select °C or °F [0=°C]
sec*10
Min. time between switching off and switching on -
OFF-ON time [expressed in tens of sec.]
sec*10
Min. time between two consecutive switch-ons -
ON-ON time [expressed in tens of sec.]
sec.
Time probe S1 remains at the boiler set point value
Num(1)
Enable Autostart function [1=active]
%
Min. speed expressed as a percentage, from 35 to
100%
%
Max. speed expressed as a percentage, from H24
to 100%
°C
Heat pump activation differential (Automatic
operation)
°C
Max. boiler water set point value (Manual
operation)
°C
Heating element activation differential (Manual
operation)
Num(1)
Enable AI2 probe [1=active]
Num(1)
Enable I2 digital input [1=active]
Num(1)
Enable I3 digital input [1=active]
Num(1)
Enable anti-bacterial treatment
Num(1)
Enable dynamic set point
Num
Balancing line tilt
°C
Outside air temperature above the value at which
balancing began
°C
Range of the outside air on which the set point
functions