The condenser fan and compressor connect and disconnect automatically when the chosen
temperature is reached. (e.g. temperature chosen 23º, the compressor and the condenser
fan disconnect at 21º and reconnect at 24º).
F1 Digital thermometer module
It indicates temperature inside vehicle. In this functioning mode, equipment is switched
off.
F2 Time programming
Hours de functioning and switching off from 0 to 9 hours. On 0 hour, it does not temporise, it
is in manual functioning F0.
-
To select hours, user will employ
keys.
+
Choose hour which appears on display, 1H (one hour), 2H (two hours)....9H (nine hours),
select F4 or F0 , equipment will be working during selected time and
and push On/Off
will stop when this time period is over.
!

Error messages

If it gives out continuous beeps when connecting the battery, the electronic control is
disconnected or poorly connected in the control panel.
E0 - Return air sensor failure.
- Low battery, less than 22.8V.
E2 - Condenser or blower fan failure.
E3 - Compressor failure
(Causes: engine, wiring, connector, lack or excess of charge).
E5 - Compressor electronic module failure due to heating.
E6 - Anti-freeze sensor failure.
10