BiAL ELS Mode D'emploi page 5

Masquer les pouces Voir aussi pour ELS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
11. While connecting the radiator to electric installation ensure that the cur-
cuit has a 30 mA residual-current circuit breaker and an appropriate over-
current circuit breaker. With the permanent installation (cable connec-
tion without plug) it is also mandatory to have an omni-pole cut-out for
disconnecting the device on all poles, by points of contact with the clear-
ance of 3 mm.
12. The device version labelled PB can be installed in bathrooms in zone 1,
as defined by applicable law, subject to any additional regulations con-
cerning electrical installations in wet areas.
Other versions of the device can be installed in Zone 2 or beyond.
13. The device is recommended for use solely as described in the manual.
14. Ensure that the heater has been installed on a wall in accordance with
its installation manual.
15. Please forward this instruction manual to the end user.
EN
5

Publicité

Table des Matières
loading

Produits Connexes pour BiAL ELS

Table des Matières