E003
Battery failure
Over-temperature protection
E004
when dis- charging the
battery.
Under-temperature
E005
protection when dis-
charging the battery.
Over-temperature protection
E006
when charging the battery.
Under-temperature
E007
protection when charging
the battery.
Under-voltage protection for
E008
the 1st cell.
Under-voltage protection for
E009
the 2nd cell.
Under-voltage protection for
E010
the 3rd cell.
Under-voltage protection for
E011
the 4th cell.
Busbar fault of inverter due
E012
to under-volt- age.
Over-load protection of
E013
inverter.
Output port of inverter is
E014
short-circuited.
The heat sink of inverter is
E015
overheated.
The temperature of the heat
E016
sink is not detected.
Over-voltage protection (PV
E017
input).
Over-voltage protection (PV
E018
output)
Over-temperature protection
E019
of heat sink for PV module
Restart the machine and charge it.
Wait for a while for it to cool down and then
restart the machine.
Wait for a while for it to heat up and then
restart the machine.
Wait for a while for it to cool down and then
restart the machine.
Wait for a while for it to heat up and then
restart the machine.
Please charge the product in time and re- start
it when fully charged.
Please charge the product in time and re- start
it when fully charged.
Please charge the product in time and re- start
it when fully charged.
Please charge the product in time and re- start
it when fully charged.
Turn off and on the machine.
Check if the output port of inverter is over-
loaded. Turn off and on the AC output to
recover.
Check if the output port of inverter is short-
circuited. Turn off and on the AC out- put to
recover.
Wait for it to cool down and then restart the
machine.
Insert the NTC and restart the machine.
Disconnect the solar charging cable and then
restart the machine.
Disconnect the solar charging cable, re- start
the machine and then re-insert the solar
charging cable.
The heat sink for PV module overheats. Wait
for it to cool down and then charge it.