GENERAL INSTALLATION INSTRUCTIONS

Ensure that the gas supply and gas type, as shown on unit nameplate, agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the
National Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2
as applicable and in accordance with local codes.
Screw the legs into the permanently fastened nuts on the four corners of the unit and tighten
by hand. Level the unit by turning the adjustment screw at the bottom of each leg. Do not
slide the unit with legs mounted, lift if necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
CAUTION: DO NOT use an open flame to check for leaks. Check all the gas piping for leaks
with a soap-and-water solution before operating the unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE
SURFACES ONLY.
Combustible clearances:
6" sides (152 mm) 6" rear (152 mm)
4" floor (102 mm)
Non-combustible clearances:
0" sides (0 mm)
0" rear (0 mm)
4" floor (102 mm)
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind
the unit by the flue. Adequate clearance for air openings into the combustion chamber is
required. Do not place objects between the bottom of the unit and the counter top. There
must be adequate clearance for removal of the front panel. All major parts, except the
burners, are removable through the front if the gas line is disconnected.
4