4-Wire Cable from Home Power Supply
IMPORTANT: Use in the US where codes do not allow grounding through neutral, New
Branch circuit installations (1996 NEC), mobile homes and RVs, new construction, and in
Canada.
A
B
C
D
A) Cable from home power supply
B) Black wires (normally L1)
C) Red wires (normally L2)
D) 4-wire flexible conduit from oven
E) Junction box
3-Wire Cable from Home Power Supply (US Only)
IMPORTANT: Use where codes allow this connection.
A
B
C
D
E
F
A) Cable from home power supply
B) Junction box
C) Black wires (normally L1)
D) White wires (normally N-neutral)
E) Green wires (normally G-ground)
1.
E
2.
F
G
3.
4.
H
I
5.
F) White wires (normally N-neutral)
G) UL-listed wire connectors
H) Green wires (normally G-ground)
I) L-listed or CSA-approved conduit connector
1.
2.
G
H
3.
4.
I
E) 4-wire flexible conduit from oven
F) Red wires (normally L2)
G) UL-listed wire connectors
H) UL-listed or CSA-approved conduit connector
Connect the 2 black wires (B) with a
UL-listed wire connector.
Connect the 2 red wires (C) with a UL-
listed wire connector.
Connect the 2 white wires (F) with a
UL-listed wire connector.
Connect the green (bare) ground wire
(H) from the oven cable to the green
(bare) ground wire in the junction box
with a UL-listed wire connector.
Install the junction-box cover.
Connect the 2 black wires (C) with a
UL-listed wire connector.
Connect the 2 white wires (D) and the
oven's green (bare) ground wire with
a UL-listed wire connector.
Connect the 2 red wires (G) with a
UL-listed wire connector.
Install the junction-box cover.