Novy 706 Mode D'emploi Et D'installation page 16

Masquer les pouces Voir aussi pour 706:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 INSTALLATION
6.1 Safety
Observe the following mounting and safety tips for
mounting:
• The installation and electrical connection of the unit
shall be carried out by an authorised expert. The
manufacturer does not accept any responsibility
for any damage resulting from faulty building in or
connection.
• Carefully take the unit from the packaging and check
it for damage before mounting. Do not mount the unit
in case of any damage.
• Check if all mounting materials have been supplied
using the drawings in section 2.2.
• The unit is intended for household use only
(preparation of food) excluding any other domestic,
commercial or indus trial use.
• Position the electrical connection such, that it is
located in the cabinet in which the cooking unit is
mounted
• Safety can only be guaranteed if the unit is connected
to an earth wire in accordance with the required
regulations.
• Do not use an extension cord for connecting to the
electricity grid.
• Replace defective or damaged parts only with original
Novy parts.
• Replace a damaged power cable with an original
Novy power cable.
• For easier mounting of the wall-mounted chimney
hood, it is recommended to do this with at least 2
persons.
• Make sure that the wall has sufficient load bearing
capacity.
6.2 Assembly
• Recommended installation height with an electric or
ceramic hob (H
-H
)(mm): 600 - 750
min
max
• • Installation height with a gas or induction hob
(H
-H
)(mm): 650-750
min
max
With the 700 series the outlet can only be pointed
upwards. Install the black plastic spigot(s) on the top.
With the 900 series the outlet can be pointed both
upwards and rearwards.
Choice of discharge direction
On models 906, 936, 939, 949, 950, the standard
discharge direction is rearward. It is also possible to
point the discharge direction upwards.
A. Outlet direction rearwards (see drawing below)
• Install the plastic spigot on the back of the hood.
• Install the flat cover plate on the top of the hood
B. Outlet direction upwards (see drawing below)
• Install the plastic spigot on the top of the hood.
• Install the cover plate with the air duct on the rear of
the hood
Wall-mounted installation
The extractor hood can be attached directly to the wall
by means of the metal installation brackets, dowels and
screws supplied.
Draw a perpendicular line on the wall (Y) at the level of
the vertical centre line of the extractor hood. Determine
the height from the hob to the underside of the extractor
hood at which the extractor hood is to be installed.
EN 16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

736739749750906936 ... Afficher tout

Table des Matières