Maintenance Instructions; Product Recycling - O'Clair PacFIRST 4.5 MONO Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8

9. MAINTENANCE INSTRUCTIONS

This operation must be obligatorily carried out by a professionally qualified
person. It should be carried out at least once a year and includes several
elements:
· Cleaning of the rear evaporator with the aid of a thin brush and a nondirty and nonchlorinated water spray.
· Revision of instructions and operating issues of the unit.
· Revision of the safety mechanisms.
· Dusting the circuit board.
· Checking the earth connections.
· Checking the gas pressure.

10. PRODUCT RECYCLING

This unit has a refrigeration gas in liquid state and electrical components. When the heat pump reaches the end of its service
life, it should be dismantled by an authorised company or may be transported to the place assigned by the corresponding local
authorities.
PacFIRST HEAT PUMP
41

Publicité

Table des Matières
loading

Table des Matières