H32 DOWN key configuration. Same as H31.
H33 ESC key configuration. Same as H31.
H42 Evaporator probe present. n (0) = not present; y (1) = present.
reL Firmware version. Device software release: read-only parameter.
tAb Parameters tAble. Reserved: read-only parameter.
COPY CARD
UL
Upload. Transfer programming parameters from instrument to CopyCard.
Fr
Formatting. Deletes data on Copy Card.
Now and not before it is possible to put the food to conserve into the refrigerator.
Place the products into the cell uniformly to allow a good internal air circulation across the cell.
Avoid obstructing the ventilation areas inside the refrigerator.
Only load the top shelf up to the stacking mark. (59)
Do not place products below the bottom shelf support. (59)
Cover or wrap food before introducing it into the refrigerator and avoid introducing warm food or steaming
liquids.
Only leave the door open for the strict amount of time necessary to introduce or remove food.
WARNING:If ambient conditions do not allow the evaporation of condense water through the automatic
system, insert container on the external bottom part or convey water toward sewerage.
In any condition and for stopping the machine it is enough to press the main switch 1 in OFF position; the
pilot light of the switch will go out. (60)
WARNING: the main switch 1 DOES NOT insulate the machine from the electric current.
Set the general cut-out in OFF position. (16)
To insulate the refrigerator from the electric current, remove the plug from the socket. (17)
THE DEFROSTING OF THE REFRIGERATING CABINETS IS TOTALLY AUTOMATIC.
The defrosting of the installations is with resistance and occurs automatically every 6 hours. The duration of
the defrosting is automatically regulated by the refrigerator. (61)
A defrost cycle can be selected at any time by pressing button "
defrost cycle will start 6 hours after pressing the button.
Alarms must be silenced by the "
Any alarm and signalling are visualized on the display:
LED
MEANING
LED compressor
if it is lit, the compressor will be turned on
if it flashes:
• the modification of the working setpoint will be running
• a compressor protection will be running (parameters C0 and C2)
LED defrost
if it is lit, the defrost will be running
ALARMS AND SIGNALS (EVERY CONTROL)
" key.
19
0...6
0...6
n/y
/
/
/
/

LOADING THE PRODUCT

" for 5 seconds. The next automatic
"POSITIVE TEMPERATURE 0/+10°C" (48a)
5
2
num
4
2
num
y
1&2
flag
12
1&2
/
6
1&2
/
/
1&2
/
/
1&2
/

STOPPING

DEFROSTING