Thermo Fisher Scientific TSG Série Manuel D'installation Et Fonctionnement page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table 5. Alarm Codes
Alarm
Trigger
code
"OPD"
Digital input
activated (H11 =
±4) (for a longer
time than tdO)
"E1"
"Pb1" probe error
"E2"
"Pb2" error
"EA"
Digital input
activated
(H11=±5)
18 |
Operation
Automatic
Outputs
clearance
Always
Registration OPd label in the AL
folder
• Alarm icon permanently ON
• Regulator blocked
Always
• Display label E1
• Alarm icon permanently ON
• Min/max alarm regulator
disabled
• Compressor operation
according to Ont and OFt
parameters
Always
Blink "E2". If configured: cut in
alarm relay, beep the buzzer
User
• Registration EA label in the AL
configured
folder.
• Alarm icon permanently ON.
• Regulation blocked if rLO=y
Comments
Door open alarm
"Pb1" sensor failure =
(short or open)
"Pb2" sensor failure =
(short or open)
External alarm