storage.
1. Disconnect the power to the ozone generator.
2. After the generator has been shut down, the pool water circulation
pump may be turned off.
3. If the system is to be shut down for an extended period,
disconnect the Ozone Tube from the unit.
3E. Water Chemistry
Regular chlorine or bromine testing should be performed as normal.
Ozone will be eliminating the majority of contaminants. Therefore,
only a small amount of chemicals will need to be added - just enough
to maintain a minimum of residual level of 0.5 - 1.0 ppm chlorine
or 1.0 - 2.0 ppm bromine. Ozone is pH neutral thus minimizing pH
adjustments.
SECTION 4. Maintenance
4A. System Electromechanical Overview
4A-1. Ozone Module
The Eclipse Ozone Generators are constructed with high voltage
Power Supply
Mouting Screws
Power Supply
Bracket
Fuse Holder
Grounding
Lugs
Figure 4: Eclipse Overview
Eclipse Installation & Operations Manual
Manifold
Ozone Module
Terminal Block
Ozone Outlet
Barb
7
Power Supply Connecter
4-2162-01 Rev.E