DO NOT OPERATE THIS EQUIPMENT WITHOUT AN AIR FILTER.
A portion of the dust entrained in the air may temporarily lodge in the air duct runs and the supply registers.
Any recirculated dust particles will be heated and charred by coming into contact with the heat exchanger.
This residue will soil ceilings, walls, drapes, carpets, furniture, and other household articles.
DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE UNIT BEFORE ATTEMPTING ANY
MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN
BE SURE THAT THE FILTER IS RE-INSTALLED WITH THE AIRFLOW DIRECTION IDENTICAL
TO ITS PREVIOUS USE. REVERSING THE FILTER WILL CAUSE DUST TRAPPED WITHIN
THE FILTER TO BREAK FREE AND RECIRCULATE WITHIN THE DUCT SYSTEM. CONSULT
YOUR INSTALLATION CONTRACTOR OR SERVICE TECHNICIAN IF YOU HAVE ANY
QUESTIONS ON INSTRUCTIONS FOR REMOVING/REINSTALLING THE AIR FILTER.
7.5

LUBRICATION

Both, indoor circulating fan motor and condenser motor are sealed bearing type motors. No lubrication required.
THE MOTOR BEARINGS WERE PRE-LUBRICATED BY THE MOTOR MANUFACTURER. DO NOT
ATTEMPT TO LUBRICATE THEM. EXCESS LUBRICATION WILL VOID THE WARRANTY, SHORTEN
THE SERVICE LIFE OF THE MOTORS, AND WILL ATTRACT THE BUILDUP OF DUST AND DIRT.
7.6

ROUTINE MAINTENANCE

QUARTERLY:
We recommend a monthly filter inspection at first, then every three months afterwards.
YEARLY:
Priming Trap needs to be inspected at every starting season. Add more water if necessary.
Check that condensate line remains clean and secured by hose clamp.
WE RECOMMEND THAT YOUR UNIT BE CHECKED BY A QUALIFIED SERVICE TECHNICIAN
It is good practice to give a quick inspection of your unit each time you inspect or clean the air fi lter.
Things to check:
Check the unit for obvious signs of deterioration.
There should be no water marks on the fl oor under the venting. Water marks may indicate a leaking pipe joint.
All ductwork should be secured to the unit, and all ductwork should be solidly supported throughout.
Water should fl ow easily through the condensate drain line. You may be able to observe this while the unit
is operating if your condensate drain line from the drain trap assembly terminates at a fl oor drain. If the
drain lines are opaque, your service technician will check them during the annual servicing.
Inspect evaporator and condenser coils for accumulations of dirt and debris – clean as required. (If the
coils appear dirty, clean them using mild detergent or a commercial coil-cleaning agent).
WARNING
!
PERSONAL INJURY OR LOSS OF LIFE.
CAUTION
!
IMPORTANT
!
IMPORTANT
!
ONCE A YEAR.
!
H3.25.1.1
!
H27.1_AC
!
!
H27.3.1.1
W415-2288 / 08.29.2019