BATTERY INSTALLATION AND BATTERY TYPESETTING (WET OR GEL/ AGM)

According to the type of batteries (WET or GEL/AGM), set the machine and electronic board of the battery charger
as follows:
WET BATTERIES
1
(NOTE: Turn the DIP switch 1
and 2 both to "OFF". )
DISCOVER EV AGM
2
BATTERIES
(NOTE: Turn the DIP switch 1
to "ON" ; 2 to "OFF" .)
GENERAL GEL/AGM
3
BATTERIES
(NOTE: Turn the DIP switch 1
and 2 both to "ON" .)
NOTE
When install new batteries please refer to figure 4 to adjust the DIP switches. Otherwise the bat-
teries may be damaged.
Machine setting
1.
Turn the ignition key (35) to "I" and in the very first seconds of machine operation pay attention to the
following:
If the first green warning light (38) is flashing, the machine is set to GEL/AGM.
If the yellow warning light (37) is flashing, the machine is set to Discover EV AGM.
If the red warning light (36) is flashing, the machine is set to WET.
2.
If the setting need to be changed, perform the following procedure.
3.
The factory setting is for discover EV AGM batteries. If the setting correspond to the battery installation, go to
step6 directly. Otherwise, follow next steps4~5.
4.
Remove the screws on control panel (C, Figure 4), then turn over the PCB (A Figure 4)to find the DIP switch
(B,Figure4) for setting battery type(WET or Discover EV AGM or GEL/AGM), (Refer to 1 or 2 or 3).
5.
If the setting complete to the battery option. Install the screws on control panel.
Battery installation
6. Open the recovery tank cover (1) and check that the recovery tank (25) is empty; otherwise empty it with the
drain hose.(22)
7. Close the recovery tank cover (1).
8. Overturn the recovery tank (25) carefully.
9. The machine is supplied with cables suitable to install 2X12V batteries. Carefully put the batteries into the
compartment, then install them correctly.
10. Route and install the battery cable as shown in (Figure3), then carefully tighten the nut on each battery terminal.
11. Place the protection cap on each terminal, then connect the battery connector (54).
12. Carefully lower the recovery tank (25).
Battery charging
13. Charge the batteries. (See procedures in maintenance chapter).
W
A G
B
R
H E
L /
O T
G E
E V
T
W E
S -
D I
C
D
Figure 4
12
ENGLISH
A
G W
R
A
L /
E
T H
G E
O
E U
T
W E
S -
D I

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

As5160t5000040150000406

Table des Matières