Wiring Diagrams

The meter can be used with single-phase or 3-phase line (3 or 4 wires);
please scrupulously respect the wiring diagram. The input configuration
must be completed with the keyboard programming of the chosen con-
nection type as well as of any external CT or VT ratios.
S 1000/232
1N1E
I N P U T
2 5 8
11
1
3
4
6
7
9
2
11
5 8
a
b
A
B
S1
L
P1
N
S 1000/245
3-2E (1-2)
I N P U T
2 5 8
11
1
3
4
6
7
9
2
5
8
a
b
a
b
A
B
A
B
S1
L1
S1
P1
L2
P1
L3
S 1000/250
3-3E
I N P U T
VOLTAGE
CURRENT
2 5 8 11 1 3
4 6 7 9
2
5
8
a
b
a
b
A
B
A
B
S1
L1
P1
S1
L2
P1
S1
L3
P1
06/16 10783371 WEB E cod.CE4DT1.AM
OUTPUTS
In the wiring diagrams always appear the configuration with pulse output
and RS485 or M-bus communication.
For the versions that are not designed for RS485 or M-Bus communication
and pulse output, you do not have to take into consideration the relevant
connections
.
S 1000/248
3-1E
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
15 29
33 34 35
34 35
2
5
8
a
b
a
A
B
A
L1
X
LOAD
L2
L3
S 1000/246
3-2E (1-3)
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
15 29
33 34 35
34 35
2
5
8
a
b
a
A
B
A
L1
X
L2
X
LOAD
X
L3
S 1000/249
3N1E
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
15 29
33 34 35
34 35
2 5 8 11
a
A
L1
X
L2
X
LOAD
X
L3
N
O U T P U T
I N P U T
RS 485
Rx / Tx GND
+ –
2 5 8
11
1
3
4
6
7
9
15 29
33 34 35
b
B
S1
P1
X
X
X
LOAD
O U T P U T
I N P U T
RS 485
Rx / Tx GND
+ –
2 5 8
11
1 3
4
6
7
9
15 29
33 34 35
b
B
S1
P1
X
X
S1
X
LOAD
P1
I N P U T
O U T P U T
RS 485
VOLTAGE
CURRENT
Rx / Tx GND
+ –
2 5 8 11 1 3
4 6 7 9
15 29
33 34 35
S1
P1
X
X
X
X X X
LOAD

Mounting Instructions

Mounting of this equipment must be carried out just by skil
led personnel.
Please make sure that the data on the label
correspond to the network on
measuring current, frequency)
which the meter must be connected.
In the wiring scrupulously respect the wiring diagram; an
error in connection unavoidably leads to wrong measure-
ments or damages to the meter.
M-Bus
When the meter is connected, conclude the mounting with
34 35
the configuration as described in the user's manual.
S 1000/247
3-2E (2-3)
I N P U T
M-Bus
34 35
2 5 8
11
1
2
5
8
a
b
a
b
A
B
A
B
L1
L2
L3
S 1000/231
3N3E
M-Bus
VOLTAGE
34 35
2 5 8 11 1 3
2 5 8 11
a
A
S1
L1
P1
L2
L3
N
Conto D4-Pt
(measuring voltage,
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
3
4
15 29
33 34 35
34 35
6
7
9
S1
X
X
S1
P1
LOAD
X
P1
O U T P U T
I N P U T
RS 485
M-Bus
Rx / Tx GND
CURRENT
+ –
4 6 7 9
33 34 35
34 35
15 29
S1
X
X
P1
S1
X
P1
LOAD
X X X
3

Publicité

Table des Matières
loading

Table des Matières