of a water distribution system intended for human consumption requires performing the
interventions in such a way as not to jeopardize the hygiene of the system.
The filter must not be installed between the boiler and the safety devices.
The plumbing systems created for the installation of equipment connected to the water supply
network must be equipped with a system capable of ensuring the non-return in the network of the
treated water, as well as with a manual or automatic by-pass valve system that allows the delivery
of untreated water, interrupting the supply of the treated one.
The filter drain connection must be conveyed into a visible drain in a stable manner.
Prevent solvents, oils, greases, acidic or caustic substances and detergents to come into contact
with the external plastic and brass parts of the equipment. In case of very strong bumps during
transport or assembly, do not install the equipment and replace it even if there are no patent
damages to the plastic parts. If the system is subject to water hammering, install an appropriate
damping system. If the water pressure can exceed the maximum operating pressure of the filter
even for short periods, install a protective pressure reducer.
Warning! Avoid overhead installation in order to prevent damages to property or persons in
the event of a fall, a collapse or water leakeges.
B1.4 Hydraulic checks after installation
After having opened the water upstream of the equipment, check for any leaks;
Check that filter is correctly positioned so as to ease ordinary maintenance operations.
Check that system is equipped with: disconnector, by-pass, sampling taps.
Verify there are no leaks from the inlet and outlet fittings and from the filter drain.
Check the compliance of the system with any local regulations or recommendations issued
by the competent local offices
For any doubt, contact Acqua Brevetti SRL (tel. +39.049.8973432, e-mail: info@acquabrevetti.it).
B1.5 Allowed assembly diagrams
PULIFIL - ENGLISH
PuliFIL is supplied without assembled covers in order to give
the possibility to:
Install the filter following the water flow direction
-
indicated by the arrow stamped on the brass filter
head;
Use the brass filter head to fix the filter to piping. The
-
hexagonal in and out brass connections offer a better
grip;
Assembly of the front cover in the front position
-