Commissioning/Start-Up; Remedy Of Faults - Oase ProfiClear Premium Compact Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
- EN -
6.

Commissioning/start-up

How to proceed:
1. Close the slide valve for the DN 75 dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Fill the container with water:
Pump fed system: Switch on the filter pump.
Gravity fed system: Open the slide valves (supply and return) of the filter series to allow the water
to flow.
4. Check all pipes, hoses and their connections for leaks.
Expansion seals may leak initially until they have fully expanded on contact with water.
5. When all filter containers are filled with water, switch on the other electrical units (e.g. filter pumps). If
using filter starters (e.g. OASE BioKick), do not operate any UVC clarifiers for at least 24 hours so as
not to disturb the colonisation of the filter media by micro-organisms.
7.

Remedy of faults

Malfunction
No flow of water
Water flow insufficient
No water is pumped out of
the container.
24
Possible cause
Filter pump not switched on
Supply to filter system or return to pond
blocked
Bottom drain, pipe or hose blocked
Hose kinked
Excessive loss in lines
Filter pump in the container is defective.
Remedy
Switch on the filter pump, connect the power plug
Clean the supply and/or return
Clean, replace if necessary
Check hose, and replace if necessary
Reduce line length to necessary minimum
Refer to the filter pump operating manual.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Proficlear premium classic

Table des Matières