Never use an old connector when installing a new range. If the hard-piping method
is used, you must carefully align the pipe; the range cannot be moved after the
connection is made.
To prevent gas leaks, apply pipe-joint compound or wrap pipe-thread tape with
Teflon on all male (external) pipe threads.
1. Install a manual gas line shut-off valve in the gas line in an easily accessed
location outside of the range.
Make sure everyone operating the range knows where and how to shut off the
gas supply to the range.
2. Install male 0.5-in (1.3-mm) flare union adapter to the 0.5-in (1.3-mm) NPT
internal thread at the regulator inlet. Use a backup wrench on the regulator
fitting to avoid damage.
When installing the range from the front, remove the 90 ° elbow for easier
installation.
3. Install male 0.5-in (1.3-mm) or 0.75-in (1.9-mm) flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care to back up the shut-off
valve to keep it from turning.
4. Connect flexible metal appliance connector to the adapter on the range.
Position range to permit connection at the shut-off valve.
5. When all connections have been made, make sure all range controls are in the
off position and turn on the main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in the system.
WARNING
Do not use a flame to check for gas leaks to prevent death, personal injury,
explosion, and/or fire hazard.
When using test pressures greater than 1/2 psig to pressure-test the gas supply
system of the residence, disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of 1/2 psig or less to test the gas
supply system, simply isolate the range from the gas supply system by closing the
individual shut-off valve.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Gas Shut-Off Valve
0.5-in or 0.75-in
Gas Pipe
Tubing Line to
Oven Burner
Adapter
Control Valve
Tubing Line
Flex
to Cooktop
Connector
Control
(6-ft max.)
Manifold
Pressure
Adapter
Regulator
NOTE
If your area requires a rigid pipe hookup,
contact a qualified installer, service agency,
or gas supplier.
NOTE
The gas shut-off valve should be installed
in an accessible location in the gas piping,
external to the appliance, for the purpose
of turning on or shutting off the gas to the
appliance.